Evidence map›Paper›PMID 33176762›Full record

ArticleBMC musculoskeletal disorders2020

Safety of the application of Rigidfix cross-pin system via different tibial tunnels for tibial fixation during anterior cruciate ligament reconstruction.

Jian Wang, Hua-Qiang Fan, Wenli Dai, Hong-Da Li, Yang-Pan Fu, Zhenhuang Liu, Chang-Ming Huang, Zhanjun Shi

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. [Research progress of tibial-graft fixation methods on anterior cruciate ligament reconstruction].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Jian WangDepartment of Orthopaedic Surgery, Nanfang hospital, Southern Medical University, Guangdong, 510515, People's Republic of China.
Hua-Qiang FanDepartment of Orthopaedic Surgery, Chenggong Hospital Affiliated to Xiamen University, Xiamen, 361003, Fujian Province, People's Republic of China.
Wenli DaiInstitute of Sports Medicine, Beijing Key Laboratory of Sports Injuries, Peking University Third Hospital, Beijing, 100191, People's Republic of China.
Hong-Da LiDepartment of Orthopaedic Surgery, Chenggong Hospital Affiliated to Xiamen University, Xiamen, 361003, Fujian Province, People's Republic of China.
Yang-Pan FuDepartment of Orthopaedic Surgery, Chenggong Hospital Affiliated to Xiamen University, Xiamen, 361003, Fujian Province, People's Republic of China.
Zhenhuang LiuDepartment of Orthopaedic Surgery, Chenggong Hospital Affiliated to Xiamen University, Xiamen, 361003, Fujian Province, People's Republic of China.
Chang-Ming HuangDepartment of Orthopaedic Surgery, Chenggong Hospital Affiliated to Xiamen University, Xiamen, 361003, Fujian Province, People's Republic of China.
Zhanjun ShiDepartment of Orthopaedic Surgery, Nanfang hospital, Southern Medical University, Guangdong, 510515, People's Republic of China. shizhanjunsmu@163.com.
Xiamen University · CNSouthern Medical University · CNPeking University Third Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWe investigate the safety of the application of the Rigidfix cross-pin system via different tibial tunnels in the tibial fixation during anterior cruciate ligament (ACL) reconstruction.

methodsFive adult fresh cadaver knees were fixed with the Rigidfix cross-pins in the tibial fixation site during ACL reconstruction. Two different tibial tunnel groups were established: in group A, the tunnel external aperture was placed at the 25° angle of coronal section; in group B, the tunnel external aperture was placed at the 45° angle of coronal section. The guide was placed at the plane 0.5 mm below articular facet through the tibial tunnel, with three rotation positions set at 0°, 30°, and 60° slopes. The incidences of iatrogenic injuries at tibial plateau cartilage (TPC), medial collateral ligament (MCL), and patellar tendon in three different slope angles were calculated in groups A and B and the results were analyzed by using chi square test.

resultsThe iatrogenic injuries at MCL, TPC, and patellar tendon could occur after the Rigidfix cross-pin system was placed 5 mm below tibial plateau cartilage for ACL reconstruction. The incidences of TPC injury (χ

conclusionsWhen the Rigidfix cross-pin system is used for ACL reconstruction at the tibial fixation site, the external aperture of tibial tunnel should not be placed at the excessively posterosuperior site, to avoid MCL and TPC injuries.

Indexed as

Anterior Cruciate Ligament InjuriesAnterior Cruciate Ligament ReconstructionAdultAnterior Cruciate LigamentBone NailsCadaverHumansKnee JointTibiaAnterior cruciate ligamentBone tunnelIatrogenic injuryRigidfixTibia

Identifiers

PMID33176762
PMCPMC7661174
OpenAlexW3102433757

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.