Trial reportPloS one2020
Measurement of fasted state gastric antral motility before and after a standard bioavailability and bioequivalence 240 mL drink of water: Validation of MRI method against concomitant perfused manometry in healthy participants.
Trial report in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03191045 (Development of MRI Protocols to Assess Gastrointestinal Motility With Concomitant Perfused Manometry Validation in Healthy Volunteers), which is not on this map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Development of MRI Protocols to Assess Gastrointestinal Motility With Concomitant Perfused Manometry Validation in Healthy Volunteers
Who cites it
9 citing papers in PubMed, 11 citations in OpenAlex.
- Gastroparesis Phenotyping: Current Methods and Emerging Opportunities With Magnetic Resonance Imaging.Neurogastroenterology and motility · 2026Review
- Painful gastric glitch: an acute epigastric pain triggered by specific food as a new phenotype of postprandial epigastric pain syndrome.BMC gastroenterology · 2026Article
- Quantitative Real-Time MRI for the Assessment of Gastric Motility.Journal of magnetic resonance imaging : JMRI · 2026Article
- Diagnosis of Functional Dyspepsia and Novel Gastrointestinal Functional Assessments.Digestion · 2026Review
- Peristalsis of the gastric conduit post-esophagectomy: is it relevant? Detailed conduit analysis using dynamic magnetic resonance imaging.Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus · 2026Observational
- Evaluation of Gastric Peristalsis Using Cine MRI in Healthy Subjects and Patients With Functional Dyspepsia.Clinical and translational gastroenterology · 2025Article
- Review
- Magnetic Resonance Imaging of the Gastrointestinal Tract: Current Role, Recent Advancements and Future Prospectives.Diagnostics (Basel, Switzerland) · 2023Review
- Quantification of the Regional Properties of Gastric Motility Using Dynamic Magnetic Resonance Images.IEEE open journal of engineering in medicine and biology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
21 authors at 4 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThe gastrointestinal environment in which drug products need to disintegrate before the drug can dissolve and be absorbed has not been studied in detail due to limitations, especially invasiveness of existing techniques. Minimal in vivo data is available on undisturbed gastrointestinal motility to improve relevance of predictive dissolution models and in silico tools such as physiologically-based pharmacokinetic models. Recent advances in magnetic resonance imaging methods could provide novel data and insights that can be used as a reference to validate and, if necessary, optimize these models. The conventional method for measuring gastrointestinal motility is via a manometric technique involving intubation. Nevertheless, it is feasible to measure gastrointestinal motility with magnetic resonance imaging. The aim of this study was is to develop and validate a magnetic resonance imaging method using the most recent semi-automated analysis method against concomitant perfused manometry method. MATERIAL AND
methodsEighteen healthy fasted participants were recruited for this study. The participants were intubated with a water-perfused manometry catheter. Subsequently, stomach motility was assessed by cine-MRI acquired at intervals, of 3.5min sets, at coronal oblique planes through the abdomen and by simultaneous water perfused manometry, before and after administration of a standard bioavailability / bioequivalence 8 ounces (~240mL) drink of water. The magnetic resonance imaging motility images were analysed using Spatio-Temporal Motility analysis STMM techniques. The area under the curve of the gastric motility contractions was calculated for each set and compared between techniques. The study visit was then repeated one week later.
resultsData from 15 participants was analysed. There was a good correlation between the MRI antral motility plots area under the curve and corresponding perfused manometry motility area under the curve (r = 0.860) during both antral contractions and quiescence.
conclusionNon-invasive dynamic magnetic resonance imaging of gastric antral motility coupled with recently developed, semi-automated magnetic resonance imaging data processing techniques correlated well with simultaneous, 'gold standard' water perfused manometry. This will be particularly helpful for research purposes related to oral absorption where the absorption of a drug is highly depending on the underlying gastrointestinal processes such as gastric emptying, gastrointestinal motility and availability of residual fluid volumes. CLINICAL TRIAL: This trial was registered at ClinicalTrials.gov as NCT03191045.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.