Evidence map›Paper›PMID 33175202›Full record

ArticleEuropean radiology2021

Development of image quality related reference doses called acceptable quality doses (AQD) in paediatric CT exams in Qatar.

Mohammad Hassan Kharita, Huda AlNaemi, Vishwanatha Kini, Shady Alkhazzam, Madan M Rehani

Open access · hybridAbstract read
In one paragraph

Article in European radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. The cumulative radiation dose paradigm in pediatric imaging.The British journal of radiology · 2021
    Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Mohammad Hassan KharitaHamad Medical Corporation, Occupational Health and Safety, Radiation Safety Section, Doha, Qatar. mhharita@hamad.qa.ORCID https://orcid.org/0000-0002-6225-1433
Huda AlNaemiHamad Medical Corporation, Occupational Health and Safety, Radiation Safety Section, Doha, Qatar.
Vishwanatha KiniHamad Medical Corporation, Occupational Health and Safety, Radiation Safety Section, Doha, Qatar.
Shady AlkhazzamHamad Medical Corporation, Occupational Health and Safety, Radiation Safety Section, Doha, Qatar.
Madan M RehaniMassachusetts General Hospital (MGH), Boston, USA.
Hamad Medical Corporation · QAMassachusetts General Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo describe first experience of integrating assessment of image quality in paediatric X-ray computed tomography (CT) with analysis of the radiation dose indices to develop reference doses called acceptable quality dose (AQD).

methodsImage quality was scored by the radiologists at a tertiary care hospital in Qatar on a scale of 0 to 4 using the recently published scoring criteria. The patients undergoing head, chest and abdomen CT were divided in different weight groups as follows: < 5 kg, 5-< 15 kg, 15-< 30 kg, 30-< 50 kg, 50-< 80 kg and > 80 kg. The images that were clinically acceptable (score of 3) were included for assessment of median values of CTDIvol and DLP to obtain AQDs in different weight groups.

resultsAfter initial training in image quality scoring of CT images of 49 patients by three radiologists, the study on 715 patients indicated 665 studies (93%) were clinically acceptable as per scoring criteria. The median CTDI

conclusionsThe first ever experience of starting with image quality assessment and integrating it with analysis of dose indices to obtain AQD values shall provide a workable model for others and values for comparison within the facility and in other facilities leading to optimisation. KEY POINTS: • The first study to integrate image quality assessment with analysis of patient dose indices shows feasibility for routine practice in other centres. • The values of acceptable quality dose (AQD) were provided for head, chest and abdomen CT of children divided into weight groups rather than age. They shall act as reference values for future studies. • Verification of our findings on proportional increase in exposure parameters (CTDIvol and DLP) with weight by other investigators shall be helpful.

Indexed as

HeadTomography, X-Ray ComputedChildHumansQatarRadiation DosageReference ValuesAbdomenHeadRadiologistTomography, X-ray computed

Identifiers

PMID33175202
PMCPMC8043894
OpenAlexW3102234647

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.