Evidence map›Paper›PMID 33173732›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2020

A Pumpless Microfluidic Neonatal Lung Assist Device for Support of Preterm Neonates in Respiratory Distress.

Mohammadhossein Dabaghi, Niels Rochow, Neda Saraei, Gerhard Fusch, Shelley Monkman, Kevin Da, Alireza Shahin-Shamsabadi, John L Brash, Dragos Predescu, Kathleen Delaney and 2 more

Open access · goldAbstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.8field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 28 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Antifouling Zwitterionic Polymer Coatings for Blood-Bearing Medical Devices.Langmuir : the ACS journal of surfaces and colloids · 2025
    Review
  6. Platelet Adhesion and Activation in an ECMO Thrombosis-on-a-Chip Model.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  7. A Clinical-Scale Microfluidic Respiratory Assist Device with 3D Branching Vascular Networks.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

12 authors at 2 institutions in 2 countries.

Mohammadhossein DabaghiSchool of Biomedical Engineering McMaster University Hamilton ON Canada.
Niels RochowDepartment of Pediatrics McMaster University Hamilton ON Canada.
Neda SaraeiDepartment of Mechanical Engineering McMaster University Hamilton ON Canada.
Gerhard FuschDepartment of Pediatrics McMaster University Hamilton ON Canada.
Shelley MonkmanDepartment of Pediatrics McMaster University Hamilton ON Canada.
Kevin DaDepartment of Chemical Engineering McMaster University Hamilton ON Canada.
Alireza Shahin-ShamsabadiSchool of Biomedical Engineering McMaster University Hamilton ON Canada.
John L BrashSchool of Biomedical Engineering McMaster University Hamilton ON Canada.
Dragos PredescuDepartment of Pediatrics McMaster University Hamilton ON Canada.
Kathleen DelaneyCentral Animal Facility Department McMaster University Hamilton ON Canada.
Christoph FuschSchool of Biomedical Engineering McMaster University Hamilton ON Canada.
P Ravi SelvaganapathySchool of Biomedical Engineering McMaster University Hamilton ON Canada.ORCID https://orcid.org/0000-0003-2041-7180
McMaster University · CANuremberg Hospital · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Premature neonates suffer from respiratory morbidity as their lungs are immature, and current supportive treatment such as mechanical ventilation or extracorporeal membrane oxygenation causes iatrogenic injuries. A non-invasive and biomimetic concept known as the "artificial placenta" (AP) would be beneficial to overcome complications associated with the current respiratory support of preterm infants. Here, a pumpless oxygenator connected to the systemic circulation supports the lung function to relieve respiratory distress. In this paper, the first successful operation of a microfluidic, artificial placenta type neonatal lung assist device (LAD) on a newborn piglet model, which is the closest representation of preterm human infants, is demonstrated. This LAD has high oxygenation capability in both pure oxygen and room air as the sweep gas. The respiratory distress that the newborn piglet is put under during experimentation, repeatedly and over a significant duration of time, is able to be relieved. These findings indicate that this LAD has a potential application as a biomimetic artificial placenta to support the respiratory needs of preterm neonates.

Indexed as

artificial placentamicrofluidicsoxygenationpiglet modelsrespiratory distress

Identifiers

PMID33173732
PMCPMC7610273
OpenAlexW3089786167

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.