Evidence map›Paper›PMID 33172465›Full record

Observational studyRespiratory research2020

Additional work of breathing from trigger errors in mechanically ventilated children.

Robert G T Blokpoel, Alette A Koopman, Jefta van Dijk, Martin C J Kneyber

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in Respiratory research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. An overview of patient-ventilator asynchrony in children.Expert review of respiratory medicine · 2025
    Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Robert G T BlokpoelDepartment of Paediatrics, Division of Paediatric Intensive Care, Beatrix Children's Hospital, University Medical Center Groningen, University of Groningen, Internal Postal Code CA 62, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands. r.g.t.blokpoel@umcg.nl.ORCID http://orcid.org/0000-0001-8607-6134
Alette A KoopmanDepartment of Paediatrics, Division of Paediatric Intensive Care, Beatrix Children's Hospital, University Medical Center Groningen, University of Groningen, Internal Postal Code CA 62, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.
Jefta van DijkDepartment of Paediatrics, Division of Paediatric Intensive Care, Beatrix Children's Hospital, University Medical Center Groningen, University of Groningen, Internal Postal Code CA 62, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.
Martin C J KneyberDepartment of Paediatrics, Division of Paediatric Intensive Care, Beatrix Children's Hospital, University Medical Center Groningen, University of Groningen, Internal Postal Code CA 62, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.
University Medical Center Groningen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPatient-ventilator asynchrony is associated with increased morbidity and mortality. A direct causative relationship between Patient-ventilator asynchrony and adverse clinical outcome have yet to be demonstrated. It is hypothesized that during trigger errors excessive pleural pressure swings are generated, contributing to increased work-of-breathing and self-inflicted lung injury. The objective of this study was to determine the additional work-of-breathing and pleural pressure swings caused by trigger errors in mechanically ventilated children.

methodsProspective observational study in a tertiary paediatric intensive care unit in an university hospital. Patients ventilated > 24 h and < 18 years old were studied. Patients underwent a 5-min recording of the ventilator flow-time, pressure-time and oesophageal pressure-time scalar. Pressure-time-product calculations were made as a proxy for work-of-breathing. Oesophageal pressure swings, as a surrogate for pleural pressure swings, during trigger errors were determined.

resultsNine-hundred-and-fifty-nine trigger errors in 28 patients were identified. The additional work-of-breathing caused by trigger errors showed great variability among patients. The more asynchronous breaths were present the higher the work-of-breathing of these breaths. A higher spontaneous breath rate led to a lower amount of trigger errors. Patient-ventilator asynchrony was not associated with prolonged duration of mechanical ventilation or paediatric intensive care stay.

conclusionsThe additional work-of-breathing caused by trigger errors in ventilated children can take up to 30-40% of the total work-of-breathing. Trigger errors were less common in patients breathing spontaneously and those able to generate higher pressure-time-product and pressure swings.

trial registrationNot applicable.

Indexed as

Respiration, ArtificialWork of BreathingAge FactorsFemaleHumansInfantIntensive Care Units, PediatricLungLung InjuryMalePressureProspective StudiesTime FactorsIneffective triggeringMechanical ventilationPaediatricPatient self-inflicted-lung injuryPatient–ventilator asynchronyWork-of-breathing

Identifiers

PMID33172465
PMCPMC7653668
OpenAlexW3104347830

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.