Evidence map›Paper›PMID 33170416›Full record

SynthesisHepatology international2020

Accuracy of contrast-enhanced ultrasound liver imaging reporting and data system: a systematic review and meta-analysis.

Jung Hee Son, Sang Hyun Choi, So Yeon Kim, So Jung Lee, Seong Ho Park, Kyung Won Kim, Hyung Jin Won, Yong Moon Shin, Pyo-Nyun Kim

Abstract readMeta-AnalysisSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Hepatology international, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jung Hee SonDepartment of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Haeundae-ro 875, Haeundae-gu, Busan, 48108, South Korea.
Sang Hyun ChoiDepartment of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, South Korea. edwardchoi83@gmail.com.ORCID http://orcid.org/0000-0002-6898-6617
So Yeon KimDepartment of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, South Korea.
So Jung LeeDepartment of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, South Korea.
Seong Ho ParkDepartment of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, South Korea.
Kyung Won KimDepartment of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, South Korea.
Hyung Jin WonDepartment of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, South Korea.
Yong Moon ShinDepartment of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, South Korea.
Pyo-Nyun KimDepartment of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, South Korea.

Funding

National Research Foundation of Korea NRF-2019R1G1A1099743
6 · The paper itself

Abstract

BACKGROUND AND

aimAfter the introduction of the contrast-enhanced ultrasound Liver Imaging Reporting and Data System (CEUS LI-RADS), several studies have reported on its performance, but the reported data vary considerably. Therefore, we performed a systematic review and meta-analysis to determine the diagnostic performance of CEUS LI-RADS in patients at risk for hepatocellular carcinoma (HCC) and investigate the causes of study heterogeneity.

methodsOriginal studies published until May 30, 2020, investigating the diagnostic performance of CEUS LI-RADS were identified in the MEDLINE, EMBASE, and Cochrane library databases. Study quality was assessed using the QUADAS-2 tool. Meta-analytic summary sensitivity and specificity for the diagnosis of HCC were calculated using a bivariate random-effects model. Meta-regression analysis was performed to explore the causes of study heterogeneity.

resultsOf the 105 articles screened, eight studies were finally analyzed (5428 hepatic observations). The summary sensitivity and specificity of CEUS LI-RADS category 5 (LR-5) for diagnosing HCC were 73% [95% confidence interval (CI) 65-79%; I

conclusionCEUS LI-RADS had high pooled specificity for diagnosing HCC but suboptimal pooled sensitivity. Substantial study heterogeneity was found, which was significantly associated with the proportion of cases of HCC and the type of reference standard.

Indexed as

UltrasonographyCarcinoma, HepatocellularContrast MediaHumansLiver NeoplasmsMagnetic Resonance ImagingRetrospective StudiesSensitivity and SpecificityContrast MediaContrast-enhanced ultrasoundDiagnostic accuracyHepatocellular carcinomaLiverLiver imaging reporting and data systemMeta-analysisSensitivitySpecificitySystematic reviewUltrasound

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.