Evidence map›Paper›PMID 33167902›Full record

Observational studyBMC ophthalmology2020

Comparison of two different optical coherence tomography angiography devices in detecting healthy versus glaucomatous eyes - an observational cross-sectional study.

A R Kee, V C H Yip, E L T Tay, C W Lim, J Cheng, H Y Teo, C H Chua, L W L Yip

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in BMC ophthalmology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Observational
  7. Article
  8. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 3 countries.

A R KeeNational Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore.
V C H YipNational Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore.
E L T TayNational Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore.
C W LimDepartment of Ophthalmology, Sarawak General Hospital, Kuching, Malaysia.
J ChengCixi Institute of Biomedical Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang Province, China.
H Y TeoNational Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore.
C H ChuaNational Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore.
L W L YipNational Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore. leonard_yip@ttsh.com.sg.
Tan Tock Seng Hospital · SGChinese Academy of Sciences · CNSarawak General Hospital · MY

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo understand the differences between two different optical coherence tomography angiography (OCTA) devices in detecting glaucomatous from healthy eyes by comparing their vascular parameters, diagnostic accuracy and test-retest reliability.

methodsA cross-sectional observational study was performed on healthy and glaucoma subjects, on whom two sets of OCTA images of optic disc and macula were acquired using both AngioVue (Optovue, USA) and Swept Source (Topcon, Japan) OCTA devices during one visit. A novel in-house software was used to calculate the vessel densities. Diagnostic accuracy of the machines in differentiating healthy versus glaucomatous eyes was determined using area under the receiver operating characteristic curve (AUROC) and test-retest repeatability of the machines was also evaluated.

resultsA total of 80 healthy and 38 glaucomatous eyes were evaluated. Glaucomatous eyes had reduced mean vessel density compared to healthy controls in all segmented layers of the optic disc and macula using AngioVue (p ≤ 0.001). However, glaucomatous eyes had higher mean vessel density on optic disc scans using Swept Source, with lack of statistically significant difference between healthy and glaucomatous eyes. The AUROC showed better diagnostic accuracy of AngioVue (0.761-1.000) compared to Swept Source (0.113-0.644). The test-retest reliability indices were generally better using AngioVue than Swept Source.

conclusionsAngioVue showed better diagnostic capability and test-retest reliability compared to Swept Source. Further studies need to be undertaken to evaluate if there is any significant difference between the various machines in diagnosing and monitoring glaucoma.

Indexed as

GlaucomaTomography, Optical CoherenceAngiographyCross-Sectional StudiesFluorescein AngiographyHumansJapanReproducibility of ResultsRetinal VesselsAngioVueDiagnosticGlaucomaOptical coherence tomography angiographyReliabilitySwept sourceVascular parametersVessel density

Identifiers

PMID33167902
PMCPMC7653880
OpenAlexW3103013351

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.