Evidence map›Paper›PMID 33163987›Full record

ArticleConference proceedings. International Conference on Image Formation in X-Ray Computed Tomography2020

Metal-Tolerant Noncircular Orbit Design and Implementation on Robotic C-Arm Systems.

Grace J Gang, Tom Russ, Yiqun Ma, Christian Toennes, Jeffrey H Siewerdsen, Lothar R Schad, J Webster Stayman

Abstract read
In one paragraph

Article in Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Revealing pelvic structures in the presence of metal hip prothesis via non-circular CBCT orbits.Proceedings of SPIE--the International Society for Optical Engineering · 2023
    Article
  4. Practical workflow for arbitrary non-circular orbits for CT with clinical robotic C-arms.Proceedings of SPIE--the International Society for Optical Engineering · 2022
    Article
  5. Universal orbit design for metal artifact elimination.Physics in medicine and biology · 2022
    Article
  6. Non-circular CBCT orbit design and realization on a clinical robotic C-arm for metal artifact reduction.Proceedings of SPIE--the International Society for Optical Engineering
    Article
  7. Fast CBCT Reconstruction using Convolutional Neural Networks for Arbitrary Robotic C-arm Orbits.Proceedings of SPIE--the International Society for Optical Engineering
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Grace J GangJohns Hopkins University, Baltimore, MD, USA.
Tom RussUniversität Heidelberg, Mannheim, Germany.
Yiqun MaJohns Hopkins University, Baltimore, MD, USA.
Christian ToennesUniversität Heidelberg, Mannheim, Germany.
Jeffrey H SiewerdsenJohns Hopkins University, Baltimore, MD, USA.
Lothar R SchadUniversität Heidelberg, Mannheim, Germany.
J Webster StaymanJohns Hopkins University, Baltimore, MD, USA.

Funding

Task-Driven 3D Interventional ImagingR01EB027127 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI STAYMAN, JOSEPH WEBSTER · 2019 to 2022
$1.8M
NIBIB NIH HHS R01 EB027127
6 · The paper itself

Abstract

Metal artifacts are a major confounding factor for image quality in CT, especially in image-guided surgery scenarios where surgical tools and implants frequently occur in the field-of-view. Traditional metal artifact correction methods typically use algorithmic solutions to interpolate over the highly attenuated projection measurements where metal is present but cannot recover the missing information obstructed by the metal. In this work, we treat metal artifacts as a missing data problem and employ noncircular orbits to maximize data completeness in the presence of metal. We first implement a local data completeness metric based on Tuy's condition as the percentage of great circles sampled by a particular orbit and accounted for the presence of metal by discounting any rays that pass through metal. We then compute the metric over many locations and many possible metal locations to reflect data completeness for arbitrary metal placements within a volume of interest. We used this metric to evaluate the effectiveness of sinusoidal orbits of different magnitudes and frequencies in metal artifact reduction. We also evaluated noncircular orbits in two imaging systems for phantoms with different metal objects and metal arrangements. Among a circular, tilted circular, and a sinusoidal orbit of two cycles per rotation, the latter is shown to most effectively remove metal artifacts. The noncircular orbit not only reduce the extent of streaks, but allows better visualization of spatial frequencies that cannot be recovered by metal artifact correction algorithms. These results illustrate the potential of relatively simple noncircular orbits to be robust against metal implants which ordinarily present significant challenges in interventional imaging.

Indexed as

Metal artifactMissing dataTuy’s condition

Identifiers

PMID33163987
PMCPMC7643882

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.