Evidence map›Paper›PMID 33162957›Full record

ArticleFrontiers in microbiology2020

Technical Validation of a Hepatitis C Virus Whole Genome Sequencing Assay for Detection of Genotype and Antiviral Resistance in the Clinical Pathway.

Carmen F Manso, David F Bibby, Kieren Lythgow, Hodan Mohamed, Richard Myers, David Williams, Renata Piorkowska, Yuen T Chan, Rory Bowden, M Azim Ansari and 4 more

Abstract read
In one paragraph

Article in Frontiers in microbiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Carmen F MansoPublic Health England, London, United Kingdom.
David F BibbyPublic Health England, London, United Kingdom.
Kieren LythgowPublic Health England, London, United Kingdom.
Hodan MohamedPublic Health England, London, United Kingdom.
Richard MyersPublic Health England, London, United Kingdom.
David WilliamsPublic Health England, London, United Kingdom.
Renata PiorkowskaPublic Health England, London, United Kingdom.
Yuen T ChanPublic Health England, London, United Kingdom.
Rory BowdenThe Wellcome Centre for Human Genetics, University of Oxford, Oxford, United Kingdom.
M Azim AnsariThe Wellcome Centre for Human Genetics, University of Oxford, Oxford, United Kingdom.
Camilla L C IpThe Wellcome Centre for Human Genetics, University of Oxford, Oxford, United Kingdom.
Eleanor BarnesPeter Medawar Building for Pathogen Research and the NIHR Oxford Biomedical Research Centre, University of Oxford, Oxford, United Kingdom.
Daniel BradshawPublic Health England, London, United Kingdom.
Jean L MbisaPublic Health England, London, United Kingdom.

Funding

Medical Research Council MR/K01532X/1Wellcome Trust
6 · The paper itself

Abstract

Choice of direct acting antiviral (DAA) therapy for Hepatitis C Virus (HCV) in the United Kingdom and similar settings usually requires knowledge of the genotype and, in some cases, antiviral resistance (AVR) profile of the infecting virus. To determine these, most laboratories currently use Sanger technology, but next-generation sequencing (NGS) offers potential advantages in throughput and accuracy. However, NGS poses unique technical challenges, which require idiosyncratic development and technical validation approaches. This applies particularly to virology, where sequence diversity is high and the amount of starting genetic material is low, making it difficult to distinguish real data from artifacts. We describe the development and technical validation of a sequence capture-based HCV whole genome sequencing (WGS) assay to determine viral genotype and AVR profile. We use clinical samples of known subtypes and viral loads, and simulated FASTQ datasets to validate the analytical performances of both the wet laboratory and bioinformatic pipeline procedures. We show high concordance of the WGS assay compared to current "gold standard" Sanger assays. Specificity was 92.3 and 96.1% for AVR and genotyping, respectively. Discordances were due to the inability of Sanger assays to assign the correct subtype or accurately call mixed drug-resistant variants. We show high repeatability and reproducibility with >99.8% sequence similarity between sequence runs as well as high precision for variant frequency detection at >98.8% in the 95th percentile. Post-sequencing bioinformatics quality control workflows allow the accurate distinction between mixed infections, cross-contaminants and recombinant viruses at a threshold of >5% for the minority population. The sequence capture-based HCV WGS assay is more accurate than legacy AVR and genotyping assays. The assay has now been implemented in the clinical pathway of England's National Health Service HCV treatment programs, representing the first validated HCV WGS pipeline in clinical service. The data generated will additionally provide granular national-level genomic information for public health policy making and support the WHO HCV elimination strategy.

Indexed as

antiviral resistancedirect acting antiviralsgenotypinghepatitis C virusnext generation sequencingtarget enrichmenttechnical validationwhole genome sequencing

Identifiers

PMID33162957
PMCPMC7583327

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.