Evidence map›Paper›PMID 33160405›Full record

SynthesisCritical care (London, England)2020

Performance of the cuff leak test in adults in predicting post-extubation airway complications: a systematic review and meta-analysis.

Akira Kuriyama, Jeffrey L Jackson, Jun Kamei

Open access · goldAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in Critical care (London, England), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
32citing papers in PubMed, 1 pooled it
4.3field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

32 citing papers in PubMed, 1 synthesis or guideline pooled it, 91 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Review
  7. Review
  8. Observational
  9. Review
  10. Review
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Position Statement of ISCCM Committee on Weaning from Mechanical Ventilator.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2024
    Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Akira KuriyamaEmergency and Critical Care Center, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki, Okayama, 710-8602, Japan. akira.kuriyama.jpn@gmail.com.ORCID 0000-0002-6633-7816
Jeffrey L JacksonDivision of General Internal Medicine, Department of Medicine, Medical College of Wisconsin, Milwaukee, USA.
Jun KameiEmergency and Critical Care Center, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki, Okayama, 710-8602, Japan.
Kurashiki Central Hospital · JPMedical College of Wisconsin · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundClinical practice guidelines recommend performing a cuff leak test in mechanically ventilated adults who meet extubation criteria to screen those at high risk for post-extubation stridor. Previous systematic reviews demonstrated excellent specificity of the cuff leak test but disagreed with respect to sensitivity. We conducted a systematic review and meta-analysis to assess the diagnostic accuracy of the cuff leak test for predicting post-extubation airway complications in intubated adult patients in critical care settings.

methodsWe searched Medline, EMBASE, Scopus, ISI Web of Science, the Cochrane Library for eligible studies from inception to March 16, 2020, without language restrictions. We included studies that examined the diagnostic accuracy of cuff leak test if post-extubation airway obstruction after extubation or reintubation was explicitly reported as the reference standard. Two authors in duplicate and independently assessed the risk of bias using the Quality Assessment for Diagnostic Accuracy Studies-2 tool. We pooled sensitivities and specificities using generalized linear mixed model approach to bivariate random-effects meta-analysis. Our primary outcomes were post-extubation airway obstruction and reintubation.

resultsWe included 28 studies involving 4493 extubations. Three studies were at low risk for all QUADAS-2 risk of bias domains. The pooled sensitivity and specificity of cuff leak test for post-extubation airway obstruction were 0.62 (95% CI 0.49-0.73; I

conclusionsThe cuff leak test has excellent specificity but moderate sensitivity for post-extubation airway obstruction. The high specificity suggests that clinicians should consider intervening in patients with a positive test, but the low sensitivity suggests that patients still need to be closely monitored post-extubation.

Indexed as

Predictive Value of TestsPressureAdultAirway ExtubationHumansSensitivity and SpecificityWeights and MeasuresAirway extubationAirway obstructionCuff leak testGuidelinesMeta-analysisSensitivity and specificity

Identifiers

PMID33160405
PMCPMC7648377
OpenAlexW3103032564

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked