Evidence map›Paper›PMID 33159558›Full record

ArticleAbdominal radiology (New York)2021

Low-dose dual-energy CT for stone characterization: a systematic comparison of two generations of split-filter single-source and dual-source dual-energy CT.

Dominik Nakhostin, Thomas Sartoretti, Matthias Eberhard, Bernhard Krauss, Daniel Müller, Hatem Alkadhi, André Euler

Abstract read
PubMed Publisher
In one paragraph

Article in Abdominal radiology (New York), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Dominik NakhostinInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistrasse 100, 8091, Zurich, Switzerland. dominik.nakhostin@usz.ch.ORCID 0000-0001-6000-3201
Thomas SartorettiInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
Matthias EberhardInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
Bernhard KraussSiemens Healthcare GmbH, An der Lände 1, 91301, Forchheim, Germany.
Daniel MüllerInstitute of Clinical Chemistry, University Hospital Zurich, University of Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
Hatem AlkadhiInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
André EulerInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
University of Zurich · CHSiemens Healthineers (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare noise texture and accuracy to differentiate uric acid from non-uric acid urinary stones among four different single-source and dual-source DECT approaches in an ex vivo phantom study.

methodsThirty-two urinary stones embedded in gelatin were mounted on a Styrofoam disk and placed into a water-filled phantom. The phantom was imaged using four different DECT approaches: (A) dual-source DECT (DS-DE); (B) 1st generation split-filter single-source DECT (SF1-TB); (C) 2nd generation split-filter single-source DECT (SF2-TB) and (D) 2nd generation split-filter single-source DECT using serial acquisitions (SF2-TS). Two different radiation doses (3 mGy and 6 mGy) were used. Noise texture was compared by assessing the average spatial frequency (f

resultsNNPS demonstrated comparable noise texture among A, C, and D (f

conclusionAccuracy to differentiate uric acid from non-uric acid stones was high among four single-source and dual-source DECT approaches for low- and routine dose DECT scans. Noise texture differed only slightly for the first-generation split-filter approach.

Indexed as

Urinary CalculiUrolithiasisHumansPhantoms, ImagingTomography, X-Ray ComputedUric AcidUric AcidKidney calculiMultidetector computed tomographyPhantoms imagingUrolithiasis

Identifiers

PMID33159558
OpenAlexW3097498951

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.