Fully printed prothrombin time sensor for point-of-care testing.

Nicholas X Williams, Brittani Carroll, Steven G Noyce, Hansel Alex Hobbie, Daniel Y Joh, Joseph G Rogers, Aaron D Franklin

Open access · greenAbstract read
In one paragraph

Article in Biosensors & bioelectronics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 23 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Nicholas X WilliamsDepartment of Electrical and Computer Engineering, Duke University, Durham, NC, 27708, USA.
Brittani CarrollDepartment of Electrical and Computer Engineering, Duke University, Durham, NC, 27708, USA.
Steven G NoyceDepartment of Electrical and Computer Engineering, Duke University, Durham, NC, 27708, USA.
Hansel Alex HobbieDepartment of Electrical and Computer Engineering, Duke University, Durham, NC, 27708, USA.
Daniel Y JohDepartment of Biomedical Engineering, Duke University, Durham, NC, 27708, USA.
Joseph G RogersDepartment of Medicine, Duke Clinical Research Institute, Duke University, Durham, NC, 27708, USA.
Aaron D FranklinDepartment of Electrical and Computer Engineering, Duke University, Durham, NC, 27708, USA; Department of Chemistry, Duke University, Durham, NC, 27708, USA. Electronic address: aaron.franklin@duke.edu.
Duke University · USClinical Research Institute · US

Funding

Medical Scientist Training Program Training GrantT32GM145449 · NIGMS · DUKE UNIVERSITY · PI Christopher D Kontos · 2022 to 2026
$6.6M
Printed Electronic Biosensors for Point-of-Care Testing of Cardiovascular BiomarkersR01HL146849 · NHLBI · DUKE UNIVERSITY · PI FRANKLIN, AARON · 2019 to 2023
$2.6M
Point of Care Testing to Improve Monitoring of LVAD PatientsR21HL141028 · NHLBI · DUKE UNIVERSITY · PI CHILKOTI, ASHUTOSH, FRANKLIN, AARON · 2018 to 2019
$421k
NHLBI NIH HHS R01 HL146849NHLBI NIH HHS R21 HL141028NIGMS NIH HHS T32 GM145449
6 · The paper itself

Abstract

With an increasing number of patients relying on blood thinners to treat medical conditions, there is a rising need for rapid, low-cost, portable testing of blood coagulation time or prothrombin time (PT). Current methods for measuring PT require regular visits to outpatient clinics, which is cumbersome and time-consuming, decreasing patient quality of life. In this work, we developed a handheld point-of-care test (POCT) to measure PT using electrical transduction. Low-cost PT sensors were fully printed using an aerosol jet printer and conductive inks of Ag nanoparticles, Ag nanowires, and carbon nanotubes. Using benchtop control electronics to test this impedance-based biosensor, it was found that the capacitive nature of blood obscures the clotting response at frequencies below 10 kHz, leading to an optimized operating frequency of 15 kHz. When printed on polyimide, the PT sensor exhibited no variation in the measured clotting time, even when flexed to a 35 mm bend radius. In addition, consistent PT measurements for both chicken and human blood illustrate the versatility of these printed biosensors under disparate operating conditions, where chicken blood clots within 30 min and anticoagulated human blood clots within 20-100 s. Finally, a low-cost, handheld POCT was developed to measure PT for human blood, yielding 70% lower noise compared to measurement with a commercial potentiostat. This POCT with printed PT sensors has the potential to dramatically improve the quality of life for patients on blood thinners and, in the long term, could be incorporated into a fully flexible and wearable sensing platform.

Indexed as

Biosensing TechniquesMetal NanoparticlesNanotubes, CarbonHumansPoint-of-Care SystemsPoint-of-Care TestingProthrombin TimeQuality of LifeSilverNanotubes, CarbonSilverCoagulationImpedancePOCTPoint-of-carePrinted electronicsProthrombin timePT/INR

Identifiers

PMID33157410
PMCPMC7903145
OpenAlexW3096814558

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.