Evidence map›Paper›PMID 33154615›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2020

Inter-Eye Vault Differences of Implantable Collamer Lens Measured Using Anterior Segment Optical Coherence Tomography.

Santiago Cerpa Manito, Angel Sánchez Trancón, Oscar Torrado Sierra, António M G Baptista, Pedro Miguel Serra

Open access · goldAbstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.0field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Advances in OCT Imaging in Myopia and Pathologic Myopia.Diagnostics (Basel, Switzerland) · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Santiago Cerpa ManitoOphthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain.
Angel Sánchez TrancónOphthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain.
Oscar Torrado SierraOphthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain.
António M G BaptistaCentre of Physics, University of Minho, Braga, Portugal.ORCID 0000-0002-7304-8756
Pedro Miguel SerraOphthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain.ORCID 0000-0003-0471-0213
Instituto Superior de Educação e Ciências · PTUniversity of Minho · PT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe distance between an implantable collamer lens (ICL) and the crystalline lens, namely vault, is a space regulated by the interaction of the ICL and the anatomical structures of the eye. This study analysed the differences in vault size between fellow eyes with similar anterior segment biometry. PATIENTS AND

methodsA retrospective case series analysed 109 cases of patients bilaterally implanted with EVO-V4c. Patients were analysed pre- and postoperatively using anterior segment optical coherence tomography. The range of vault inter-eye differences was defined as the 95% confidence interval of the differences. Bivariate correlation was applied to seek for associations between vault inter-eye differences with biometric and lens parameters (angle-to-angle, anterior chamber depth, crystalline lens rise, central corneal thickness, central keratometry, ICL spherical equivalent, horizontal compression, postoperative pupil diameter and vault).

resultsMean vault inter-eye differences were similar between fellow eyes (26.0 ± 122.5 µm). The 95% confidence interval range of the differences was ±240.1 µm, nearly 50% of the cases presented vault inter-eye differences higher than 100 µm. The vault of the first operated eye explained 81% of the variance in the second eye vault. Vault inter-eye differences were positively correlated with the level of horizontal compression and with vault magnitude.

conclusionVaults measured in fellow eyes may present considerable differences, which can reach 25% of the common vault range. This reflects some degree of baseline variability in the vault. Clinically, these differences assume special relevance in cases where low or high vaults are expected.

Indexed as

implantable collamer lensesinter-eye differencesvariabilityvault

Identifiers

PMID33154615
PMCPMC7605967
OpenAlexW3097780774

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.