Evidence map›Paper›PMID 33153440›Full record

ArticleBMC musculoskeletal disorders2020

A new fluoroscopic view for evaluation of anteromedial cortex reduction quality during cephalomedullary nailing for intertrochanteric femur fractures: the 30° oblique tangential projection.

Shi-Yi Chen, Shi-Min Chang, Rujan Tuladhar, Zhen Wei, Wen-Feng Xiong, Sun-Jun Hu, Shou-Chao Du

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
  4. [Positive cortical support reduction in treatment of trochanteric femur fractures: history in theory establishment and its inspiration for clinical innovations].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Review
  5. [Anteromedial cortical support reduction in treatment of trochanteric femur fractures: a ten-year reappraisal].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. [Standard radiographic images in cephalomedullary nailing fixation for intertrochanteric femoral fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Article
  13. Article
  14. Accuracy of radiographic projections to guide cephalic screw position in pertrochanteric fracture: a cadaveric study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shi-Yi ChenDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China.
Shi-Min ChangDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China. shiminchang11@aliyun.com.
Rujan TuladharDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China.
Zhen WeiDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China.
Wen-Feng XiongDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China.
Sun-Jun HuDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China.
Shou-Chao DuDepartment of Orthopaedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China.

Funding

National Natural Science Foundation of China 81772323
6 · The paper itself

Abstract

backgroundAnteromedial cortex-to-cortex reduction is a key parameter for stable reconstruction of the fracture fragments during the intertrochanteric fracture fixation. This paper introduces the oblique fluoroscopic projection as a novel method to evaluate the quality of anteromedial cortical apposition.

methodsThree proximal femur specimens were marked with steel wires along five anatomic landmarks: Greater trochanter, Lesser trochanter, Intertrochanteric line, Anterolateral tubercle and the Anteromedial cortical line. After obtaining the standard femoral neck AP and lateral fluoroscopic images, the C-arm was rotated by every 5°increments until a clear tangential view of the antero-medial-inferior corner cortex was observed. 98 cases of intertrochanteric hip fractures were enrolled from April 2018 to October 2019. After fixation with the nails, the intra-operative anteromedial cortex reduction quality was evaluated from the AP, the true lateral, and the new anteromedial oblique fluoroscopic images. The fluoroscopic results were compared with the post-operative 3D-CT reconstruction images.

resultsThe specimen study showed that internal rotation of the C-arm to approximately 30 ° can remove all the obscure shadows and clearly display the antero-medial-inferior cortical tangent line. Clinically,the positive, neutral and negative apposition of different cortices via intra-operative fluoroscopic images showed79, 19 and 0 cases of medial cortical apposition in AP views; 2, 68 and 28 cases of anterior cortices in lateral views;and 22, 51 and 25cases of anteromedial cortical apposition in oblique views respectively. The post-operative 3D-CT reconstruction images revealed that the final anteromedial cortical contact was noted in 62 cases (63.3%), and lost in 36 cases (36.7%). The overall coincidence rate between intra-operative fluoroscopy and post-operative 3D-CT was 63.3% (62/98) in AP view,79.6% (78/98) in lateral view, and 86.7% (85/98) in oblique view(p < 0.001). Negative cortical apposition in oblique view was highly predictive of a final loss of cortical support on 3D CT (24/25 cases, 96%).And non-negative cortical apposition in oblique view was highly associated with true cortical support on 3D CT images (61/73 cases, 83.6%) (p < 0.001).

conclusionsBesides the AP and lateral projections, an anteromedial oblique view of 30° certifies to be a very useful means for evaluation of the fracture reduction quality of anteromedial cortical apposition.

Indexed as

Fracture Fixation, IntramedullaryHip FracturesFemurFluoroscopyFracture FixationFracture Fixation, InternalHumans3D-CTAnteromedial cortexCortical appositionFluoroscopyOblique viewPertrochanteric fracture

Identifiers

PMID33153440
PMCPMC7643444

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.