Evidence map›Paper›PMID 33149970›Full record

ArticleBiomedical optics express2020

Deep learning model for ultrafast quantification of blood flow in diffuse correlation spectroscopy.

Chien-Sing Poon, Feixiao Long, Ulas Sunar

Abstract read
In one paragraph

Article in Biomedical optics express, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Deep Learning in Biomedical Optics.Lasers in surgery and medicine · 2021
    Review
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Chien-Sing PoonDepartment of Biomedical Engineering, Wright State University, 207 Russ Engineering Center, 3640 Colonel Glenn Hwy., Dayton, OH 45435, USA.ORCID https://orcid.org/0000-0002-3064-8209
Feixiao LongBeijing QED Technique Co., Ltd., Beijing, China.
Ulas SunarDepartment of Biomedical Engineering, Wright State University, 207 Russ Engineering Center, 3640 Colonel Glenn Hwy., Dayton, OH 45435, USA.ORCID https://orcid.org/0000-0002-0623-7522

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Diffuse correlation spectroscopy (DCS) is increasingly used in the optical imaging field to assess blood flow in humans due to its non-invasive, real-time characteristics and its ability to provide label-free, bedside monitoring of blood flow changes. Previous DCS studies have utilized a traditional curve fitting of the analytical or Monte Carlo models to extract the blood flow changes, which are computationally demanding and less accurate when the signal to noise ratio decreases. Here, we present a deep learning model that eliminates this bottleneck by solving the inverse problem more than 2300% faster, with equivalent or improved accuracy compared to the nonlinear fitting with an analytical method. The proposed deep learning inverse model will enable real-time and accurate tissue blood flow quantification with the DCS technique.

Identifiers

PMID33149970
PMCPMC7587273

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.