Validation of a wearable cuff-less wristwatch-type blood pressure monitoring device.

Joon Ho Moon, Myung-Kyun Kang, Chang-Eun Choi, Jeonghee Min, Hae-Young Lee, Soo Lim

Registry-linked trialOpen access · goldAbstract readValidation Study
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06627920 (Validation of a Smartwatch for Blood Pressure Measurement), which is not on this map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
4.9field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06627920 completednot on this mapstarted 2024, after this paper: background citation

Validation of a Smartwatch for Blood Pressure Measurement

TypeobservationalSponsorEuropean University Miguel de CervantesRan2024 to 2024Enrolled101ConditionsBlood Pressure, Heart Rate, Oxygen SaturationArmsUse of the KC08 smartwatch, Beurer PO30 and Omron M7 BP monitor.
3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 54 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Joon Ho MoonDepartment of Internal Medicine, Seoul National University College of Medicine, Seoul, South Korea.
Myung-Kyun KangInBody Co., Ltd, Seoul, South Korea.
Chang-Eun ChoiInBody Co., Ltd, Seoul, South Korea.
Jeonghee MinDepartment of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, South Korea.
Hae-Young LeeDepartment of Internal Medicine, Seoul National University College of Medicine, Seoul, South Korea.
Soo LimDepartment of Internal Medicine, Seoul National University College of Medicine, Seoul, South Korea. limsoo@snu.ac.kr.
Genbody (South Korea) · KRSeoul National University Bundang Hospital · KRSeoul National University · KRSeoul National University Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ambulatory blood pressure (BP) monitoring is recommended to improve the management of hypertension. Here, we investigated the accuracy of BP estimated using a wearable cuff-less device, InBodyWATCH, compared with BP measured using a manual sphygmomanometer. Thirty-five adults were enrolled (age 57.1 ± 17.9 years). The BP was estimated using InBodyWATCH with an individualized estimation based on a neural network model. Three paired sets of BPs from the two devices were compared using correlation analysis and Bland-Altman plots (n = 105 paired BP readings). The correlations for both systolic and diastolic BP (SBP and DBP) between the two devices were high (r = 0.964 and 0.939, both P < 0.001). The mean difference was 2.2 ± 6.1 mmHg for SBP and -0.2 ± 4.2 mmHg for DBP; these were not significant (P = 0.472 for SBP and P = 0.880 for DBP). The proportions of estimated SBP/DBP obtained from the InBodyWATCH within ± 5 mmHg of manual SBP/DBP were 71.4%/83.8%; within ± 10 mmHg they were 86.7%/98.1%; and within ± 15 mmHg they were 97.1%/99.0%. The estimated BP from this wearable cuff-less device correlated highly with the manual BP and showed good accuracy, suggesting its potential to be used in ambulatory BP monitoring.

Indexed as

Wearable Electronic DevicesWristAdultAgedAlgorithmsBlood Pressure Monitoring, AmbulatoryCalibrationElectrocardiographyFemaleHumansMaleMiddle AgedPulse Wave AnalysisSphygmomanometers

Identifiers

PMID33149118
PMCPMC7642418
OpenAlexW3095143238

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.