Evidence map›Paper›PMID 33147197›Full record

ArticleJournal of synchrotron radiation2020

A coded aperture microscope for X-ray fluorescence full-field imaging.

D P Siddons, A J Kuczewski, A K Rumaiz, R Tappero, M Idir, K Nakhoda, J Khanfri, V Singh, E R Farquhar, M Sullivan and 3 more

Open access · hybridAbstract read
In one paragraph

Article in Journal of synchrotron radiation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 6 institutions in 1 country.

D P SiddonsNational Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA.
A J KuczewskiNational Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA.
A K RumaizNational Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA.ORCID 0000-0002-9907-299X
R TapperoNational Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA.
M IdirNational Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA.
K NakhodaNational Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA.
J KhanfriStony Brook University, Stony Brook, NY 11794, USA.ORCID 0000-0003-4150-817X
V SinghLouisiana State University, Baton Rouge, LA 70803, USA.
E R FarquharCase Western Reserve University, Cleveland, OH 44106, USA.ORCID 0000-0002-6419-038X
M SullivanCase Western Reserve University, Cleveland, OH 44106, USA.
D AbelCase Western Reserve University, Cleveland, OH 44106, USA.
D J BradyDuke University, Durham, NC 27708, USA.
X YuanNokia Bell Labs, Murray Hill, NJ 07974, USA.ORCID 0000-0002-8311-7524
Brookhaven National Laboratory · USCase Western Reserve University · USDuke University · USLouisiana State University · USNokia (United States) · USStony Brook University · US

Funding

Case Center for Synchrotron BiosciencesP30EB009998 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI CHANCE, MARK R · 2009 to 2018
$8.4M
NIBIB NIH HHS P30 EB009998The DOE Office of Science by Brookhaven National Laboratory DE-SC0012704The National Institutes of Health P30-EB-009998The National Science Foundation, Division of Biological Infrastructure 1228549The U.S. Department of Energy, Office of Science, Biological and Environmental Research FWP PS018
6 · The paper itself

Abstract

The design and construction of an instrument for full-field imaging of the X-ray fluorescence emitted by a fully illuminated sample are presented. The aim is to produce an X-ray microscope with a few micrometers spatial resolution, which does not need to scan the sample. Since the fluorescence from a spatially inhomogeneous sample may contain many fluorescence lines, the optic which will provide the magnification of the emissions must be achromatic, i.e. its optical properties must be energy-independent. The only optics which fulfill this requirement in the X-ray regime are mirrors and pinholes. The throughput of a simple pinhole is very low, so the concept of coded apertures is an attractive extension which improves the throughput by having many pinholes, and retains the achromatic property. Modified uniformly redundant arrays (MURAs) with 10 µm openings and 50% open area have been fabricated using gold in a lithographic technique, fabricated on a 1 µm-thick silicon nitride membrane. The gold is 25 µm thick, offering good contrast up to 20 keV. The silicon nitride is transparent down into the soft X-ray region. MURAs with various orders, from 19 up to 73, as well as their respective negative (a mask where open and closed positions are inversed compared with the original mask), have been made. Having both signs of mask will reduce near-field artifacts and make it possible to correct for any lack of contrast.

Indexed as

coded aperturefluorescencefull-fieldX-ray microscope

Identifiers

PMID33147197
PMCPMC7642964
OpenAlexW3093712943

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.