Evidence map›Paper›PMID 33146417›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2021

Biomechanical evaluation of total ankle arthroplasty. Part I: Joint loads during simulated level walking.

Brett D Steineman, Fernando J Quevedo González, Daniel R Sturnick, Jonathan T Deland, Constantine A Demetracopoulos, Timothy M Wright

Abstract read
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Brett D SteinemanDepartment of Biomechanics, Hospital for Special Surgery, New York, USA.ORCID 0000-0002-7419-6734
Fernando J Quevedo GonzálezDepartment of Biomechanics, Hospital for Special Surgery, New York, USA.ORCID 0000-0001-6521-8754
Daniel R SturnickDepartment of Biomechanics, Hospital for Special Surgery, New York, USA.
Jonathan T DelandFoot and Ankle Service, Hospital for Special Surgery, New York, USA.
Constantine A DemetracopoulosFoot and Ankle Service, Hospital for Special Surgery, New York, USA.
Timothy M WrightDepartment of Biomechanics, Hospital for Special Surgery, New York, USA.

Funding

Disparities in COVID Disease Severity and Outcomes in New York CityUL1TR002384 · NCATS · WEILL MEDICAL COLL OF CORNELL UNIV · PI JULIANNE L IMPERATO-MCGINLEY · 2017 to 2026
$86.2M
J. NRSA Training CoreTL1TR002386 · NCATS · WEILL MEDICAL COLL OF CORNELL UNIV · PI Genevieve Giny Fouda Amou ou · 2017 to 2026
$5.8M
NCATS NIH HHS TL1 TR002386NCATS NIH HHS UL1 TR002384
6 · The paper itself

Abstract

In total ankle arthroplasty, the interaction at the joint between implant and bone is driven by a complex loading environment. Unfortunately, little is known about the loads at the ankle during daily activities since earlier attempts use two- or three-dimensional models to explore simplified joint mechanics. Our goal was to develop a framework to calculate multi-axial loads at the joint during simulated level walking following total ankle arthroplasty. To accomplish this, we combined robotic simulations of level walking at one-quarter bodyweight in three cadaveric foot and ankle specimens with musculoskeletal modeling to calculate the multi-axial forces and moments at the ankle during the stance phase. The peak compressive forces calculated were between 720 and 873 N occurring around 77%-80% of stance. The peak moment, which was the internal moment for all specimens, was between 6.1 and 11.6 N m and occurred between 72% and 88% of the stance phase. The peak moment did not necessarily occur with the peak force. The ankle joint loads calculated in this study correspond well to previous attempts in the literature; however, our robotic simulator and framework provide an opportunity to resolve the resultant three-dimensional forces and moments as others have not in previous studies. The framework may be useful to calculate ankle joint loads in cadaveric specimens as the first step in evaluating bone-implant interactions in total ankle replacement using specimen specific inputs. This approach also provides a unique opportunity to evaluate changes in joint loads and kinematics following surgical interventions of the foot and ankle.

Indexed as

Arthroplasty, Replacement, AnkleFinite Element AnalysisModels, BiologicalAnkle JointBiomechanical PhenomenaFemaleHumansMaleMiddle AgedWalkingWeight-Bearinganklebiomechanicsjoint reaction loadsmusculoskeletal modelingtotal ankle arthroplasty

Identifiers

PMID33146417
PMCPMC7749051

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.