Evidence map›Paper›PMID 33142935›Full record

ArticleSensors (Basel, Switzerland)2020

Label-Free Oligonucleotide-Based SPR Biosensor for the Detection of the Gene Mutation Causing Prothrombin-Related Thrombophilia.

Rodrigo Sierpe, Marcelo J Kogan, Soledad Bollo

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Rodrigo SierpeLaboratorio de Biosensores, Facultad de Ciencias Químicas y Farmacéuticas, Universidad de Chile; Santos Dumont N° 964, Independencia, Santiago 8380492, Chile.ORCID 0000-0001-7104-6215
Marcelo J KoganLaboratorio de Nanobiotecnología y Nanotoxicología, Facultad de Ciencias Químicas y Farmacéuticas, Universidad de Chile; Santos Dumont N° 964, Independencia, Santiago 8380492, Chile.
Soledad BolloLaboratorio de Biosensores, Facultad de Ciencias Químicas y Farmacéuticas, Universidad de Chile; Santos Dumont N° 964, Independencia, Santiago 8380492, Chile.ORCID 0000-0003-0868-4294
Pontificia Universidad Católica de Chile · CL

Funding

Comisión Nacional de Investigación Científica y Tecnológica FONDAP 15130011Comisión Nacional de Investigación Científica y Tecnológica FONDECYT 1161225Comisión Nacional de Investigación Científica y Tecnológica fondecyt 3180706Comisión Nacional de Investigación Científica y Tecnológica FONDEQUIP EQM 140112
6 · The paper itself

Abstract

Prothrombin-related thrombophilia is a genetic disorder produced by a substitution of a single DNA base pair, replacing guanine with adenine, and is detected mainly by polymerase chain reaction (PCR). A suitable alternative that could detect the single point mutation without requiring sample amplification is the surface plasmon resonance (SPR) technique. SPR biosensors are of great interest: they offer a platform to monitor biomolecular interactions, are highly selective, and enable rapid analysis in real time. Oligonucleotide-based SPR biosensors can be used to differentiate complementary sequences from partially complementary or noncomplementary strands. In this work, a glass chip covered with an ultrathin (50 nm) gold film was modified with oligonucleotide strands complementary to the mutated or normal (nonmutated) DNA responsible for prothrombin-related thrombophilia, forming two detection platforms called mutated thrombophilia (MT) biosensor and normal thrombophilia (NT) biosensor. The results show that the hybridization response is obtained in 30 min, label free and with high reproducibility. The sensitivity obtained in both systems was approximately 4 ΔμRIU/nM. The dissociation constant and limits of detection calculated were 12.2 nM and 20 pM (3 fmol), respectively, for the MT biosensor, and 8.5 nM and 30 pM (4.5 fmol) for the NT biosensor. The two biosensors selectively recognize their complementary strand (mutated or normal) in buffer solution. In addition, each platform can be reused up to 24 times when the surface is regenerated with HCl. This work contributes to the design of the first SPR biosensor for the detection of prothrombin-related thrombophilia based on oligonucleotides with single point mutations, label-free and without the need to apply an amplification method.

Indexed as

Biosensing TechniquesOligonucleotidesThrombophiliaHumansPoint MutationProthrombinReproducibility of ResultsSurface Plasmon ResonanceOligonucleotidesProthrombinbiosensorsoligonucleotidessurface plasmon resonancethrombophilia

Identifiers

PMID33142935
PMCPMC7663036
OpenAlexW3096995890

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.