ArticleSensors (Basel, Switzerland)2020
Development of Washable Silver Printed Textile Electrodes for Long-Term ECG Monitoring.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Silver-Induced Contact Dermatitis From Electrocardiography Monitoring Electrodes: A Case Report.Cureus · 2026Article
- Applications of Smart Textiles for Ambulatory Electrocardiogram Monitoring: Scoping Review of the Literature.JMIR cardio · 2026Article
- Performance comparison of conductive textile electrodes in ECG monitoring.Frontiers in bioengineering and biotechnology · 2026Article
- Screen Printing Conductive Inks on Textiles: Impact of Plasma Treatment.Sensors (Basel, Switzerland) · 2025Article
- E-Textiles for Sports and Fitness Sensing: Current State, Challenges, and Future Opportunities.Sensors (Basel, Switzerland) · 2024Review
- Advances in Printed Electronic Textiles.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Review
- Recent Advances and Challenges in Textile Electrodes for Wearable Biopotential Signal Monitoring: A Comprehensive Review.Biosensors · 2023Review
- Evaluation of Novel Embroidered Textile-Electrodes Made from Hybrid Polyamide Conductive Threads for Surface EMG Sensing.Sensors (Basel, Switzerland) · 2023Article
- Self-Healing, Reconfigurable, Thermal-Switching, Transformative Electronics for Health Monitoring.Advanced materials (Deerfield Beach, Fla.) · 2023Article
- Characterization and Validation of Flexible Dry Electrodes for Wearable Integration.Sensors (Basel, Switzerland) · 2023Article
- Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis.Sensors (Basel, Switzerland) · 2022Article
- Smart Electronic Textiles for Wearable Sensing and Display.Biosensors · 2022Review
- Measuring Biosignals with Single Circuit Boards.Bioengineering (Basel, Switzerland) · 2022Review
- Article
- Wearable Smart Textiles for Long-Term Electrocardiography Monitoring-A Review.Sensors (Basel, Switzerland) · 2021Review
- Integration of Conductive Materials with Textile Structures, an Overview.Sensors (Basel, Switzerland) · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Long-term electrocardiography (ECG) monitoring is very essential for the early detection and treatment of cardiovascular disorders. However, commercially used silver/silver chloride (Ag/AgCl) electrodes have drawbacks, and these become more obvious during long-term signal monitoring, making them inconvenient for this use. In this study, we developed silver printed textile electrodes from knitted cotton and polyester fabric for ECG monitoring. The surface resistance of printed electrodes was 1.64 Ω/sq for cotton and 1.78 Ω/sq for polyester electrodes. The ECG detection performance of the electrodes was studied by placing three electrodes around the wrist where the electrodes were embedded on an elastic strap with Velcro. The ECG signals collected using textile electrodes had a comparable waveform to those acquired using standard Ag/AgCl electrodes with a signal to noise ratio (SNR) of 33.10, 30.17, and 33.52 dB for signals collected from cotton, polyester, and Ag/AgCl electrodes, respectively. The signal quality increased as the tightness of the elastic strap increased. Signals acquired at 15 mmHg pressure level with the textile electrodes provided a similar quality to those acquired using standard electrodes. Interestingly, the textile electrodes gave acceptable signal quality even after ten washing cycles.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.