ArticleQuantitative imaging in medicine and surgery2020
Optimizing accuracy of freehand cannulation of the ipsilateral ventricle for intracranial pressure monitoring in patients with brain trauma.
Article in Quantitative imaging in medicine and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 3 citations in OpenAlex.
- Non-invasive detection of intracranial pressure related to the optic nerve.Quantitative imaging in medicine and surgery · 2021Review
- Multimodal Simulation of a Novel Device for a Safe and Effective External Ventricular Drain Placement.Frontiers in neuroscience · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIntracranial pressure (ICP) monitoring in traumatic brain injury (TBI) usually requires the placement of a catheter into the ipsilateral ventricle. This surgical procedure is commonly performed via a freehand method using surface anatomical landmarks as guides. The current accuracy of the catheter placement remains relatively low and even lower among TBI patients. This study was undertaken to optimize the freehand ventricular cannulation to increase the accuracy for TBI. The authors hypothesized that an optimal surgical plan of cannulation should give an operator the greatest degrees of freedom, which could be measured as the range of operation angle, range of catheter placement depth, and size of the target area.
methodsAn imaging simulation was first performed using the computed tomography (CT) images of 47 adult patients with normal brain anatomy. On the reconstructed 3D head model, four different coronal planes of ventricular cannulation were identified: a 4-cm anterior, a 2-cm anterior, a standard (central), and a 2-cm posterior plane. The degrees of freedom during the cannulation procedure were determined, including the relevant angles, lengths of cannulation, cross-sectional area, and bounding rectangle of the lateral ventricle. Next, a retrospective assessment was performed on the CT scans of another 111 patients with TBI who underwent freehand ventricular cannulation for ICP monitoring. Postoperative measurements were also performed based on CT images to calculate the accuracy and safety of catheter placement between coronal planes in practice.
resultsOur simulation results showed that the 2-cm anterior plane had more extensive degrees of freedom for ventricular cannulation, in terms of length of catheter trajectory (7% longer, P<0.001), cross-sectional area of the lateral ventricle (14% larger, P=0.046), and length of the lateral ventricle (17% wider, P<0.001) than that of the standard plane, while both the 4-cm anterior and 2-cm posterior planes did not offer advantages over the standard plane in these ways. The mean length range of catheter trajectory in the 2-cm anterior plane was 41 to 58 mm. Retrospective assessment of TBI patients with ICP monitor placement also confirmed our simulation data. It showed that the accuracy of ipsilateral ventricle cannulation in the 2-cm anterior plane was 70.6%, which was a significant increase from 42.9% in the standard plane (P=0.007).
conclusionsOur imaging simulation and retrospective study demonstrate that different coronal planes could provide different degrees of freedom for cannulation, the 2-cm anterior plane has the greatest degrees of freedom in terms of larger target area and greater length range of the trajectory. The optimized surgical plan in this manner could improve cannulation accuracy and benefit a significant number of TBI patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.