Evidence map›Paper›PMID 33137128›Full record

ArticlePloS one2020

Patient-reported long-term benefit with an active transcutaneous bone-conduction device.

Julia Hundertpfund, Jens Eduard Meyer, Attila Óvári

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. The COVID-19 pandemic and upgrades of CI speech processors for children: part II-hearing outcomes.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2022
    Article
  3. Long-term audiological benefit with an active transcutaneous bone-conduction device: a retrospective cohort analysis.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Julia HundertpfundAsklepios Medical School, Semmelweis University, Hamburg, Germany.
Jens Eduard MeyerAsklepios Medical School, Semmelweis University, Hamburg, Germany.
Attila ÓváriAsklepios Medical School, Semmelweis University, Hamburg, Germany.ORCID 0000-0003-4610-6890
MSH Medical School Hamburg – University of Applied Sciences and Medical University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the long-term benefits in hearing-related quality of life, patient satisfaction and wearing time of patients rehabilitated with an active transcutaneous bone-conduction device. Adverse events and audiological outcomes are reported as secondary outcomes.

methodsThis retrospective, mono-centric cohort analysis involves 16 adults with conductive or mixed hearing loss with a mean device experience of 51.25 months. Patient-reported outcome measures were assessed using the short version of the Speech, Spatial and Qualities of Hearing Scale (SSQ12-B) and the German version of the Audio Processor Satisfaction Questionnaire (APSQ). Audiological outcomes as well as incidence of adverse events were obtained from patients´ charts.

resultsThe hearing-related quality of life improved significantly within all subscales of the SSQ12-B scoring a mean overall of 2.95 points. Patient satisfaction measured with the APSQ scored 8.8 points on average. Wearing times differed considerably and patients with lower levels of education seemed to use their device longer compared to patients with academic education. Eight minor adverse events were documented, all of which resolved during follow-up. The mean gain in word recognition score at the last follow-up measured at 65 dB was 75.9%, while speech reception threshold was lowered by 35.1 dB.

conclusionEven after several years, patients report significant benefits in hearing-related quality of life and device satisfaction. In combination with a low rate of minor adverse events and significantly improved audiological outcomes, the device is considered as a comfortable and effective option in hearing rehabilitation.

Indexed as

Hearing AidsAdolescentAdultAgedAged, 80 and overAuditory ThresholdBone ConductionChildChild, PreschoolFemaleHearing Loss, ConductiveHearing Loss, Mixed Conductive-SensorineuralHumansInfantMaleMiddle Aged

Identifiers

PMID33137128
PMCPMC7605656
OpenAlexW3097522979

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.