ArticleEar and hearing
Effects of Head Movements on Sound-Source Localization in Single-Sided Deaf Patients With Their Cochlear Implant On Versus Off.
Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 22 citations in OpenAlex.
- The influence of postural load and early aging on dynamic sound localization: Evidence for reduced cognitive-motor reserve.Attention, perception & psychophysics · 2026Article
- Impact of Acute Versus Chronic Unilateral Hearing Loss on Head Movement in a Novel Binaural Task.The Laryngoscope · 2026Article
- Incomplete binaural restoration in single-sided deafness treated with cochlear implants: insights from compensatory head-orienting behaviors.Frontiers in neuroscience · 2026Article
- Evaluating Auditory Localization Capabilities in Young Patients with Single-Side Deafness.Audiology research · 2025Article
- Sound-seeking before and after hearing loss in mice.Scientific reports · 2024Article
- Spatial hearing training in virtual reality with simulated asymmetric hearing loss.Scientific reports · 2024Article
- Sound-seeking before and after hearing loss in mice.bioRxiv : the preprint server for biology · 2024Article
- Randomizing spectral cues used to resolve front-back reversals in sound-source localization.The Journal of the Acoustical Society of America · 2023Article
- Dynamic spectral cues do not affect human sound localization during small head movements.Frontiers in neuroscience · 2023Article
- Instant improvement in monaural spatial hearing abilities through cognitive feedback.Experimental brain research · 2022Article
- Effects of Bilateral Automatic Gain Control Synchronization in Cochlear Implants With and Without Head Movements: Sound Source Localization in the Frontal Hemifield.Journal of speech, language, and hearing research : JSLHR · 2021Article
- Proficiency in Using Level Cue for Sound Localization Is Related to the Auditory Cortical Structure in Patients With Single-Sided Deafness.Frontiers in neuroscience · 2021Article
- Differing postural control patterns in individuals with bilateral and unilateral hearing loss.American journal of otolaryngologyArticle
- Children With Bilateral Cochlear Implants Show Emerging Spatial Hearing of Stationary and Moving Sound.Trends in hearingArticle
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
objectivesWe investigated the ability of single-sided deaf listeners implanted with a cochlear implant (SSD-CI) to (1) determine the front-back and left-right location of sound sources presented from loudspeakers surrounding the listener and (2) use small head rotations to further improve their localization performance. The resulting behavioral data were used for further analyses investigating the value of so-called "monaural" spectral shape cues for front-back sound source localization.
designEight SSD-CI patients were tested with their cochlear implant (CI) on and off. Eight normal-hearing (NH) listeners, with one ear plugged during the experiment, and another group of eight NH listeners, with neither ear plugged, were also tested. Gaussian noises of 3-sec duration were band-pass filtered to 2-8 kHz and presented from 1 of 6 loudspeakers surrounding the listener, spaced 60° apart. Perceived sound source localization was tested under conditions where the patients faced forward with the head stationary, and under conditions where they rotated their heads between (Equation is included in full-text article.).
results(1) Under stationary listener conditions, unilaterally-plugged NH listeners and SSD-CI listeners (with their CIs both on and off) were nearly at chance in determining the front-back location of high-frequency sound sources. (2) Allowing rotational head movements improved performance in both the front-back and left-right dimensions for all listeners. (3) For SSD-CI patients with their CI turned off, head rotations substantially reduced front-back reversals, and the combination of turning on the CI with head rotations led to near-perfect resolution of front-back sound source location. (4) Turning on the CI also improved left-right localization performance. (5) As expected, NH listeners with both ears unplugged localized to the correct front-back and left-right hemifields both with and without head movements.
conclusionsAlthough SSD-CI listeners demonstrate a relatively poor ability to distinguish the front-back location of sound sources when their head is stationary, their performance is substantially improved with head movements. Most of this improvement occurs when the CI is off, suggesting that the NH ear does most of the "work" in this regard, though some additional gain is introduced with turning the CI on. During head turns, these listeners appear to primarily rely on comparing changes in head position to changes in monaural level cues produced by the direction-dependent attenuation of high-frequency sounds that result from acoustic head shadowing. In this way, SSD-CI listeners overcome limitations to the reliability of monaural spectral and level cues under stationary conditions. SSD-CI listeners may have learned, through chronic monaural experience before CI implantation, or with the relatively impoverished spatial cues provided by their CI-implanted ear, to exploit the monaural level cue. Unilaterally-plugged NH listeners were also able to use this cue during the experiment to realize approximately the same magnitude of benefit from head turns just minutes after plugging, though their performance was less accurate than that of the SSD-CI listeners, both with and without their CI turned on.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.