Evidence map›Paper›PMID 33136640›Full record

ArticleEar and hearing

Effects of Head Movements on Sound-Source Localization in Single-Sided Deaf Patients With Their Cochlear Implant On Versus Off.

M Torben Pastore, Sarah J Natale, Colton Clayton, Michael F Dorman, William A Yost, Yi Zhou

Open access · greenAbstract read
In one paragraph

Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Sound-seeking before and after hearing loss in mice.bioRxiv : the preprint server for biology · 2024
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

M Torben PastoreCollege of Health Solutions, Arizona State University, Tempe, Arizona, USA.
Sarah J Natale
Colton Clayton
Michael F Dorman
William A Yost
Yi Zhou
Arizona State University · US

Funding

Dynamic Sound Source LocalizationR01DC015214 · NIDCD · ARIZONA STATE UNIVERSITY-TEMPE CAMPUS · PI YOST, WILLIAM ALBERT · 2016 to 2020
$1.6M
Minimizing auditory spatial ambiguities using listener rotation for normal and hearing impaired listenersF32DC017676 · NIDCD · ARIZONA STATE UNIVERSITY-TEMPE CAMPUS · PI PASTORE, MICHAEL TORBEN · 2018 to 2021
$196k
NIDCD NIH HHS F32 DC017676NIDCD NIH HHS R01 DC015214
6 · The paper itself

Abstract

objectivesWe investigated the ability of single-sided deaf listeners implanted with a cochlear implant (SSD-CI) to (1) determine the front-back and left-right location of sound sources presented from loudspeakers surrounding the listener and (2) use small head rotations to further improve their localization performance. The resulting behavioral data were used for further analyses investigating the value of so-called "monaural" spectral shape cues for front-back sound source localization.

designEight SSD-CI patients were tested with their cochlear implant (CI) on and off. Eight normal-hearing (NH) listeners, with one ear plugged during the experiment, and another group of eight NH listeners, with neither ear plugged, were also tested. Gaussian noises of 3-sec duration were band-pass filtered to 2-8 kHz and presented from 1 of 6 loudspeakers surrounding the listener, spaced 60° apart. Perceived sound source localization was tested under conditions where the patients faced forward with the head stationary, and under conditions where they rotated their heads between (Equation is included in full-text article.).

results(1) Under stationary listener conditions, unilaterally-plugged NH listeners and SSD-CI listeners (with their CIs both on and off) were nearly at chance in determining the front-back location of high-frequency sound sources. (2) Allowing rotational head movements improved performance in both the front-back and left-right dimensions for all listeners. (3) For SSD-CI patients with their CI turned off, head rotations substantially reduced front-back reversals, and the combination of turning on the CI with head rotations led to near-perfect resolution of front-back sound source location. (4) Turning on the CI also improved left-right localization performance. (5) As expected, NH listeners with both ears unplugged localized to the correct front-back and left-right hemifields both with and without head movements.

conclusionsAlthough SSD-CI listeners demonstrate a relatively poor ability to distinguish the front-back location of sound sources when their head is stationary, their performance is substantially improved with head movements. Most of this improvement occurs when the CI is off, suggesting that the NH ear does most of the "work" in this regard, though some additional gain is introduced with turning the CI on. During head turns, these listeners appear to primarily rely on comparing changes in head position to changes in monaural level cues produced by the direction-dependent attenuation of high-frequency sounds that result from acoustic head shadowing. In this way, SSD-CI listeners overcome limitations to the reliability of monaural spectral and level cues under stationary conditions. SSD-CI listeners may have learned, through chronic monaural experience before CI implantation, or with the relatively impoverished spatial cues provided by their CI-implanted ear, to exploit the monaural level cue. Unilaterally-plugged NH listeners were also able to use this cue during the experiment to realize approximately the same magnitude of benefit from head turns just minutes after plugging, though their performance was less accurate than that of the SSD-CI listeners, both with and without their CI turned on.

Indexed as

Cochlear ImplantationCochlear ImplantsSound LocalizationHead MovementsHumansReproducibility of Results

Identifiers

PMID33136640
PMCPMC7772279
OpenAlexW3039687114

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.