ArticleEar and hearing
Speech-in-Noise Recognition With More Realistic Implementations of a Binaural Cochlear-Implant Sound Coding Strategy Inspired by the Medial Olivocochlear Reflex.
Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Binaural audio frontend processing for cochlear implants inspired by the medial olivocochlear reflex.Frontiers in neuroscience · 2025Article
- Magnitude of the contralateral efferent olivocochlear effect as a function of the frequency.Journal of otology · 2022Article
- Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update.Journal of the Association for Research in Otolaryngology : JARO · 2021Review
- Understanding degraded speech leads to perceptual gating of a brainstem reflex in human listeners.PLoS biology · 2021Article
- Further simulations of the effect of cochlear-implant pre-processing and head movement on interaural level differences.The Journal of the Acoustical Society of America · 2021Article
- The role of efferents in human auditory development: efferent inhibition predicts frequency discrimination in noise for children.Journal of neurophysiology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesCochlear implant (CI) users continue to struggle understanding speech in noisy environments with current clinical devices. We have previously shown that this outcome can be improved by using binaural sound processors inspired by the medial olivocochlear (MOC) reflex, which involve dynamic (contralaterally controlled) rather than fixed compressive acoustic-to-electric maps. The present study aimed at investigating the potential additional benefits of using more realistic implementations of MOC processing.
designEight users of bilateral CIs and two users of unilateral CIs participated in the study. Speech reception thresholds (SRTs) for sentences in competition with steady state noise were measured in unilateral and bilateral listening modes. Stimuli were processed through two independently functioning sound processors (one per ear) with fixed compression, the current clinical standard (STD); the originally proposed MOC strategy with fast contralateral control of compression (MOC1); a MOC strategy with slower control of compression (MOC2); and a slower MOC strategy with comparatively greater contralateral inhibition in the lower-frequency than in the higher-frequency channels (MOC3). Performance with the four strategies was compared for multiple simulated spatial configurations of the speech and noise sources. Based on a previously published technical evaluation of these strategies, we hypothesized that SRTs would be overall better (lower) with the MOC3 strategy than with any of the other tested strategies. In addition, we hypothesized that the MOC3 strategy would be advantageous over the STD strategy in listening conditions and spatial configurations where the MOC1 strategy was not.
resultsIn unilateral listening and when the implant ear had the worse acoustic signal-to-noise ratio, the mean SRT was 4 dB worse for the MOC1 than for the STD strategy (as expected), but it became equal or better for the MOC2 or MOC3 strategies than for the STD strategy. In bilateral listening, mean SRTs were 1.6 dB better for the MOC3 strategy than for the STD strategy across all spatial configurations tested, including a condition with speech and noise sources colocated at front where the MOC1 strategy was slightly disadvantageous relative to the STD strategy. All strategies produced significantly better SRTs for spatially separated than for colocated speech and noise sources. A statistically significant binaural advantage (i.e., better mean SRTs across spatial configurations and participants in bilateral than in unilateral listening) was found for the MOC2 and MOC3 strategies but not for the STD or MOC1 strategies.
conclusionsOverall, performance was best with the MOC3 strategy, which maintained the benefits of the originally proposed MOC1 strategy over the STD strategy for spatially separated speech and noise sources and extended those benefits to additional spatial configurations. In addition, the MOC3 strategy provided a significant binaural advantage, which did not occur with the STD or the original MOC1 strategies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.