Evidence map›Paper›PMID 33126491›Full record

ArticleSensors (Basel, Switzerland)2020

Acceleration Magnitude at Impact Following Loss of Balance Can Be Estimated Using Deep Learning Model.

Tae Hyong Kim, Ahnryul Choi, Hyun Mu Heo, Hyunggun Kim, Joung Hwan Mun

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tae Hyong KimDepartment of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 440-746, Korea.ORCID 0000-0001-7355-3886
Ahnryul ChoiDepartment of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 440-746, Korea.
Hyun Mu HeoDepartment of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 440-746, Korea.
Hyunggun KimDepartment of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 440-746, Korea.
Joung Hwan MunDepartment of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 440-746, Korea.

Funding

National Research Foundation of Korea No. 2019M3E5D1A01068999
6 · The paper itself

Abstract

Pre-impact fall detection can detect a fall before a body segment hits the ground. When it is integrated with a protective system, it can directly prevent an injury due to hitting the ground. An impact acceleration peak magnitude is one of key measurement factors that can affect the severity of an injury. It can be used as a design parameter for wearable protective devices to prevent injuries. In our study, a novel method is proposed to predict an impact acceleration magnitude after loss of balance using a single inertial measurement unit (IMU) sensor and a sequential-based deep learning model. Twenty-four healthy participants participated in this study for fall experiments. Each participant worn a single IMU sensor on the waist to collect tri-axial accelerometer and angular velocity data. A deep learning method, bi-directional long short-term memory (LSTM) regression, is applied to predict a fall's impact acceleration magnitude prior to fall impact (a fall in five directions). To improve prediction performance, a data augmentation technique with increment of dataset is applied. Our proposed model showed a mean absolute percentage error (MAPE) of 6.69 ± 0.33% with r value of 0.93 when all three different types of data augmentation techniques are applied. Additionally, there was a significant reduction of MAPE by 45.2% when the number of training datasets was increased by 4-fold. These results show that impact acceleration magnitude can be used as an activation parameter for fall prevention such as in a wearable airbag system by optimizing deployment process to minimize fall injury in real time.

Indexed as

Accidental FallsDeep LearningWearable Electronic DevicesAccelerationHumansdata augmentationdeep learningfallingpeak impact acceleration magnitudepre-impact fall detectionwearable fall protective device

Identifiers

PMID33126491
PMCPMC7663134

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.