Evidence map›Paper›PMID 33125595›Full record

ArticleGeneral thoracic and cardiovascular surgery2021

Computational fluid dynamics simulations of flow distribution and graft designs in apicoaortic bypass.

Takashi Sasaki, Hitomi Ueda, Keiichi Itatani, Kenji Suzuki, Jiro Kurita, Shun-Ichiro Sakamoto, Yasuo Miyagi, Yosuke Ishii, Tetsuro Morota, Takashi Nitta

Abstract readCase Reports
PubMed Publisher
In one paragraph

Article in General thoracic and cardiovascular surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Takashi SasakiDepartment of Cardiovascular Surgery, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan. t-sasaki0@nms.ac.jp.ORCID http://orcid.org/0000-0002-4313-1102
Hitomi UedaDepartment of Cardiovascular Surgery, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan.
Keiichi ItataniDepartment of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, Kyoto, Japan.
Kenji SuzukiDepartment of Cardiovascular Surgery, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan.
Jiro KuritaDepartment of Cardiovascular Surgery, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan.
Shun-Ichiro SakamotoDepartment of Cardiovascular Surgery, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan.
Yasuo MiyagiDepartment of Cardiovascular Surgery, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan.
Yosuke IshiiDepartment of Cardiovascular Surgery, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan.
Tetsuro MorotaDepartment of Cardiovascular Surgery, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan.
Takashi NittaDepartment of Cardiovascular Surgery, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveApicoaortic bypass has double outlets and its graft design is similar to that of a left ventricular assist device (LVAD). The left ventricular apex to the descending aorta (LV-DsAo) bypass is widely used in apicoaortic bypass. In contrast, the left ventricular apex to the ascending aorta (LV-AsAo) bypass is standard in LVAD surgery. This study aimed to evaluate the graft designs of apicoaortic bypass and their effects on flow distribution and energy loss (EL).

methodsA simulation study using computational fluid dynamics was performed on the geometry and hemodynamics data obtained from a 30-year-old patient who underwent a LV-DsAo bypass. The ratio of the cardiac output (CO) through the ascending aorta (AsAo) and apicoaortic conduit was set at 50:50, 30:70, and 10:90. Regional blood flow (RBF) and EL were calculated for the different distribution ratios. As an alternative to the LV-DsAo bypass, a virtual LV-AsAo bypass surgery was performed, and each parameter was compared with that of the LV-DsAo bypass.

resultsAt a distribution ratio of 50:50, the RBF to the head and EL were 16.4% of the total CO and 62.0 mW in the LV-DsAo bypass, and 32.3% and 81.5 mW in the LV-AsAo bypass, respectively. The RBF to the head decreased with the CO through the AsAo in the LV-DsAo bypass, but it was constant in the LV-AsAo bypass. The EL increased inversely with the CO through the AsAo in both graft designs.

conclusionThe regional blood flow distribution was different, but the trend of the EL which increased inversely with the CO through the AsAo was similar between the LV-DsAo and LV-AsAo bypasses.