Evidence map›Paper›PMID 33125457›Full record

ArticleAnesthesiology2021

Aerosol Retention Characteristics of Barrier Devices.

Richard L Fidler, Christopher R Niedek, Justin J Teng, Mary E Sturgeon, Qi Zhang, David L Robinowitz, Jan Hirsch

Open access · bronzeAbstract read
In one paragraph

Article in Anesthesiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.0field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 29 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 1 institution in 3 countries.

Richard L Fidler
Christopher R Niedek
Justin J Teng
Mary E Sturgeon
Qi Zhang
David L Robinowitz
Jan Hirsch
San Francisco VA Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDisease severity in coronavirus disease 2019 (COVID-19) may be associated with inoculation dose. This has triggered interest in intubation barrier devices to block droplet exposure; however, aerosol protection with these devices is not known. This study hypothesized that barrier devices reduce aerosol outside of the barrier.

methodsAerosol containment in closed, semiclosed, semiopen, and open barrier devices was investigated: (1) "glove box" sealed with gloves and caudal drape, (2) "drape tent" with a drape placed over a frame, (3) "slit box" with armholes and caudal end covered by vinyl slit diaphragms, (4) original "aerosol box," (5) collapsible "interlocking box," (6) "simple drape" over the patient, and (7) "no barrier." Containment was investigated by (1) vapor instillation at manikin's right arm with video-assisted visual evaluation and (2) submicrometer ammonium sulfate aerosol particles ejected through the manikin's mouth with ventilation and coughs. Samples were taken from standardized locations inside and around the barriers using a particle counter and a mass spectrometer. Aerosol evacuation from the devices was measured using standard hospital suction, a surgical smoke evacuator, and a Shop-Vac.

resultsVapor experiments demonstrated leakage via arm holes and edges. Only closed and semiclosed devices and the aerosol box reduced aerosol particle counts (median [25th, 75th percentile]) at the operator's mouth compared to no barrier (combined median 29 [-11, 56], n = 5 vs. 157 [151, 166], n = 5). The other barrier devices provided less reduction in particle counts (133 [128, 137], n = 5). Aerosol evacuation to baseline required 15 min with standard suction and the Shop-Vac and 5 min with a smoke evacuator.

conclusionsBarrier devices may reduce exposure to droplets and aerosol. With meticulous tucking, the glove box and drape tent can retain aerosol during airway management. Devices that are not fully enclosed may direct aerosol toward the laryngoscopist. Aerosol evacuation reduces aerosol content inside fully enclosed devices. Barrier devices must be used in conjunction with body-worn personal protective equipment. EDITOR’S PERSPECTIVE:

Indexed as

Personal Protective EquipmentAerosolsCoughCOVID-19Health PersonnelHumansIntubation, IntratrachealOccupational ExposureAerosols

Identifiers

PMID33125457
PMCPMC7687877
OpenAlexW3095942464

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.