Evidence map›Paper›PMID 33125415›Full record

ArticlePloS one2020

MiniVStimA: A miniaturized easy to use implantable electrical stimulator for small laboratory animals.

Manfred Bijak, Martin Schmoll, Jonathan C Jarvis, Ewald Unger, Hermann Lanmüller

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.5field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Muscle Plasticity, Adaptation and Epigenetics.Advances in experimental medicine and biology · 2025
    Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Manfred BijakCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.ORCID 0000-0001-5577-7536
Martin SchmollCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Jonathan C JarvisFaculty of Science, John Moores University, Liverpool, United Kingdom.
Ewald UngerCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Hermann LanmüllerCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Medical University of Vienna · ATLiverpool John Moores University · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

According to PubMed, roughly 10% of the annually added publications are describing findings from the small animal model (mice and rats), including investigations in the field of muscle physiology and training. A subset of this research requires neural stimulation with flexible adjustments of stimulation parameters, highlighting the need for reliable implantable electrical stimulators, small enough (~1 cm3), that even mice can tolerate them without impairing their movement. The MiniVStimA is a battery-powered implant for nerve stimulation with an outer diameter of 15 mm and an encapsulated volume of 1.2 cm3 in its smallest variation. It can be pre-programmed according to the experimental protocol and controlled after implantation with a magnet. It delivers constant current charge-balanced monophasic rectangular pulses up to 2 mA and 1 ms phase width (1 kΩ load). The circuitry is optimized for small volume and energy efficiency. Due to the variation of the internal oscillator (31 kHz ± 10%), calibration measures must be implemented during the manufacturing process, which can reduce the deviation of the frequency related parameters down to ± 1%. The expected lifetime of the smaller (larger) version is 100 (480) days for stimulation with 7 Hz all day and 10 (48) days for stimulation with 100 Hz. Devices with complex stimulation patterns for nerve stimulation have been successfully used in two in-vivo studies, lasting up to nine weeks. The implant worked fully self-contained while the animal stayed in its familiar environment. External components are not required during the entire time.

Indexed as

Electrodes, ImplantedAnimalsAnimals, LaboratoryElectric StimulationEquipment DesignFemaleMiceRatsRats, Wistar

Identifiers

PMID33125415
PMCPMC7598460
OpenAlexW3095279475

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked