Design and Experiment of Assistive Mechanism for Adjustment of Transrectal Ultrasound Probe.

Jin-Gang Jiang, Hui Zuo, Yong-De Zhang, Zhi-Yuan Huang, Xiao-Wei Guo, Yong Xu

Abstract read
In one paragraph

Article in Applied bionics and biomechanics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jin-Gang JiangKey Laboratory of Advanced Manufacturing and Intelligent Technology, Ministry of Education, Harbin University of Science and Technology, Harbin 150080, China.ORCID https://orcid.org/0000-0003-0491-9236
Hui ZuoKey Laboratory of Advanced Manufacturing and Intelligent Technology, Ministry of Education, Harbin University of Science and Technology, Harbin 150080, China.
Yong-De ZhangKey Laboratory of Advanced Manufacturing and Intelligent Technology, Ministry of Education, Harbin University of Science and Technology, Harbin 150080, China.
Zhi-Yuan HuangKey Laboratory of Advanced Manufacturing and Intelligent Technology, Ministry of Education, Harbin University of Science and Technology, Harbin 150080, China.
Xiao-Wei GuoKey Laboratory of Advanced Manufacturing and Intelligent Technology, Ministry of Education, Harbin University of Science and Technology, Harbin 150080, China.
Yong XuUrinary Surgery, The General Hospital of Chinese People's Liberation Army, Beijing 100039, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transrectal ultrasound prostate biopsy is the most commonly used method for the diagnosis of prostate cancer. During the operation, the doctor needs to manually adjust the ultrasound probe for repeated adjustments, which is difficult to ensure the efficiency, accuracy, and safety of the operation. This paper presents a passive posture adjusting mechanism of transrectal ultrasound probe. The overall mechanism has 7 degrees of freedom, consisting of a position adjustment module, a posture adjustment module, and an ultrasonic probe rotation and feed module. In order to achieve the centering function, the posture adjustment module is designed based on the double parallelogram. Centering performance is verified based on SimMechanics, and remote center point error of physical prototypes is evaluated. The maximum error of the azimuth remote center point motion and the maximum error of the remote center point motion of the ultrasonic probe are 4 mm and 3.4 mm, respectively, which are less than the anus that can withstand 6 mm. Meanwhile, the analysis of measurement error shows that the random error correlation is weak in different directions, the systematic error confidence intervals of azimuth and elevation angle are less than 2.5 mm, and the maximum relative fixed point error and the maximum relative standard error are 14.73% and 14.98%, respectively. The simulation and testing results have shown the effectiveness and reliability of the propose mechanism.