Evidence map›Paper›PMID 33121506›Full record

ArticleJournal of orthopaedic surgery and research2020

Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study.

Shuang G Yan, Yan Chevalier, Fanxiao Liu, Xingyi Hua, Anna Schreiner, Volkmar Jansson, Florian Schmidutz

Open access · goldAbstract readComparative Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed, 2 pooled it
3.9field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 2 syntheses or guidelines pooled it, 31 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Shuang G YanDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Anhui Medical University, No.1 Baicao Road, Hefei, 230088, China. yanshuanggen686@hotmail.com.
Yan ChevalierDepartment of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University of Munich (LMU), Munich, Germany.
Fanxiao LiuDepartment of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University of Munich (LMU), Munich, Germany.
Xingyi HuaDepartment of Orthopaedic Surgery, The First Affiliated Hospital of Anhui Medical University, No.1 Baicao Road, Hefei, 230088, China.
Anna SchreinerBG Trauma Center Tuebingen, Eberhard Karls University Tuebingen, Schnarrenbergstrasse 95, 72076, Tuebingen, Germany.
Volkmar JanssonDepartment of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University of Munich (LMU), Munich, Germany.
Florian SchmidutzDepartment of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University of Munich (LMU), Munich, Germany.
First Affiliated Hospital of Anhui Medical University · CNLudwig-Maximilians-Universität München · DEUniversity of Tübingen · DEShandong Provincial Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundShort stem total hip arthroplasty (SHA) preserves femoral bone stock and is supposed to provide a more natural load transfer compared to standard stem total hip arthroplasty (THA). As comparative biomechanical reference data are rare we used a finite element analysis (FEA) approach to compare cortical load transfer after implantations of a metaphyseal anchoring short and standard stem in native biomechanical femora.

methodsThe subject specific finite element models of biomechanical femora, one native and two with implanted metaphyseal anchoring SHA (Metha, B. Braun Aesculap) and standard THA (CLS, Zimmer-Biomet), were generated from computed tomography datasets. The loading configuration was performed with an axial force of 1400 N. Von Mises stress was used to investigate the change of cortical stress distribution.

resultsCompared to the native femur, a considerable reduction of cortical stress was recorded after implantation of SHA and standard THA. The SHA showed less reduction proximally with a significant higher metaphyseal cortical stress compared to standard THA. Moreover, the highest peak stresses were observed metaphyseal for the SHA stem while for the standard THA high stress pattern was observed more distally.

conclusionsBoth, short and standard THA, cause unloading of the proximal femur. However, the metaphyseal anchoring SHA features a clearly favorable pattern in terms of a lower reduction proximally and improved metaphyseal loading, while standard THA shows a higher proximal unloading and more distal load transfer. These load patterns implicate a reduced stress shielding proximally for metaphyseal anchoring SHA stems and might be able to translate in a better bone preservation.

Indexed as

Finite Element AnalysisHip ProsthesisArthroplasty, Replacement, HipBiomechanical PhenomenaBone DensityFemurHumansProsthesis DesignStress, MechanicalFinite element analysisSHAStemStress shieldingTotal hip arthroplasty

Identifiers

PMID33121506
PMCPMC7597026
OpenAlexW3095121387

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked