Evidence map›Paper›PMID 33114773›Full record

ArticleSensors (Basel, Switzerland)2020

Characterization and Miniaturization of Silver-Nanoparticle Microcoil via Aerosol Jet Printing Techniques for Micromagnetic Cochlear Stimulation.

Ressa Reneth Sarreal, Pamela Bhatti

Open access · goldAbstract readLetter
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.8field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 12 citations in OpenAlex.

  1. Aerosol Jet Printing for Neuroprosthetic Device Development.Bioengineering (Basel, Switzerland) · 2025
    Review
  2. Microfabrication Technologies for Nanoinvasive and High-Resolution Magnetic Neuromodulation.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Review
  3. Promising Applications of Nanoparticles in the Treatment of Hearing Loss.Frontiers in cell and developmental biology · 2021
    Review
  4. Bioprinting of Collagen Type I and IIFrontiers in bioengineering and biotechnology · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Ressa Reneth SarrealCollege of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.ORCID 0000-0002-5835-0041
Pamela BhattiCollege of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
Georgia Institute of Technology · US

Funding

National Science Foundation 1055801, 1809334, 1827321
6 · The paper itself

Abstract

According to the National Institute of Deafness and other Communication Disorders 2012 report, the number of cochlear implant (CI) users is steadily increasing from 324,000 CI users worldwide. The cochlea, located in the inner ear, is a snail-like structure that exhibits a tonotopic geometry where acoustic waves are filtered spatially according to frequency. Throughout the cochlea, there exist hair cells that transduce sensed acoustic waves into an electrical signal that is carried by the auditory nerve to ultimately reach the auditory cortex of the brain. A cochlear implant bridges the gap if non-functional hair cells are present. Conventional CIs directly inject an electrical current into surrounding tissue via an implanted electrode array and exploit the frequency-to-place mapping of the cochlea. However, the current is dispersed in perilymph, a conductive bodily fluid within the cochlea, causing a spread of excitation. Magnetic fields are more impervious to the effects of the cochlear environment due to the material properties of perilymph and surrounding tissue, demonstrating potential to improve precision. As an alternative to conventional CI electrodes, the development and miniaturization of microcoils intended for micromagnetic stimulation of intracochlear neural elements is described. As a step toward realizing a microcoil array sized for cochlear implantation, human-sized coils were prototyped via aerosol jet printing. The batch reproducible aerosol jet printed microcoils have a diameter of 1800 μm, trace width and trace spacing of 112.5 μm, 12 μm thickness, and inductance values of approximately 15.5 nH. Modelling results indicate that the coils have a combined depolarization-hyperpolarization region that spans 1.5 mm and produce a more restrictive spread of activation when compared with conventional CI.

Indexed as

Cochlear ImplantsDeafnessMiniaturizationNanoparticlesAcoustic StimulationAerosolsCochleaElectric StimulationHumansPrinting, Three-DimensionalSilverAerosolsSilveraerosol jet printingcochlear stimulationmicrocoilsensor applications

Identifiers

PMID33114773
PMCPMC7663185
OpenAlexW3097962551

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.