Evaluating attenuation correction strategies in a dedicated, single-gantry breast PET-tomosynthesis scanner.

Srilalan Krishnamoorthy, Trevor Vent, Bruno Barufaldi, Andrew D A Maidment, Joel S Karp, Suleman Surti

Open access · greenAbstract readEvaluation Study
In one paragraph

Article in Physics in medicine and biology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Next generation tomosynthesis image acquisition optimization for dedicated PET-DBT attenuation corrections.Proceedings of SPIE--the International Society for Optical Engineering · 2021
    Article
  7. Novel Perlin-based Phantoms Using 3D Models of Compressed Breast Shape and Fractal Noise.Proceedings of SPIE--the International Society for Optical Engineering
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Srilalan KrishnamoorthyDepartment of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America.
Trevor VentDepartment of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States of America.
Bruno BarufaldiDepartment of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America.
Andrew D A MaidmentDepartment of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America.
Joel S KarpDepartment of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America.
Suleman SurtiDepartment of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America.
University of Pennsylvania · US

Funding

Time-of-Flight PET for Improved Whole-Body ImagingR01CA113941 · NCI · UNIVERSITY OF PENNSYLVANIA · PI JOEL S KARP, Suleman Surti · 2006 to 2026
$9.8M
High Performance, Quantitative Breast PET Scanner Integrated With TomosynthesisR01CA196528 · NCI · UNIVERSITY OF PENNSYLVANIA · PI ANDREW DOUGLAS ARNOLD MAIDMENT, Suleman Surti · 2016 to 2026
$5.9M
Optimization of Clinical and Research PET ImagingR01EB028764 · NIBIB · UNIVERSITY OF PENNSYLVANIA · PI SURTI, SULEMAN · 2020 to 2023
$2.2M
Energy-Based Scatter Estimation Algorithm for Accurate Quantitative PET ImagingR21CA239177 · NCI · UNIVERSITY OF PENNSYLVANIA · PI SURTI, SULEMAN · 2019 to 2020
$370k
NCI NIH HHS R01 CA113941NCI NIH HHS R01 CA196528NCI NIH HHS R21 CA239177NIBIB NIH HHS R01 EB028764
6 · The paper itself

Abstract

We are developing a dedicated, combined breast positron emission tomography (PET)-tomosynthesis scanner. Both the PET and digital breast tomosynthesis (DBT) scanners are integrated in a single gantry to provide spatially co-registered 3D PET-tomosynthesis images. The DBT image will be used to identify the breast boundary and breast density to improve the quantitative accuracy of the PET image. This paper explores PET attenuation correction (AC) strategies that can be performed with the combined breast PET-DBT scanner to obtain more accurate, quantitative high-resolution 3D PET images. The PET detector is comprised of a 32 × 32 array of 1.5 × 1.5 × 15 mm

Indexed as

Phantoms, ImagingBreastBreast NeoplasmsFemaleHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMammographyPositron-Emission Tomography

Identifiers

PMID33113520
PMCPMC7870546
OpenAlexW3095090757

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.