Evidence map›Paper›PMID 33111663›Full record

ArticleHealth technology assessment (Winchester, England)2020

Non-contact infrared thermometers compared with current approaches in primary care for children aged 5 years and under: a method comparison study.

Ann Van den Bruel, Jan Verbakel, Kay Wang, Susannah Fleming, Gea Holtman, Margaret Glogowska, Elizabeth Morris, George Edwards, Fatene Abakar Ismail, Kathryn Curtis and 8 more

Open access · diamondAbstract readComparative StudyMulticenter Study
In one paragraph

Article in Health technology assessment (Winchester, England), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Multiparametric identification of subclinical atrial fibrillation after an embolic stroke of undetermined source.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2023
    Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors at 2 institutions in 3 countries.

Ann Van den BruelNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.
Jan VerbakelNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.
Kay WangNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0002-7195-1730
Susannah FlemingNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0001-7205-2051
Gea HoltmanNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0001-6579-767X
Margaret GlogowskaNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0001-8029-1052
Elizabeth MorrisNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0002-9913-6041
George EdwardsNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0002-0048-4178
Fatene Abakar IsmailNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0002-1463-7980
Kathryn CurtisNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0001-5367-9182
James GoetzNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0003-2439-8116
Grace BarnesNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0003-4296-1689
Ralitsa SlivkovaNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0002-2810-2266
Charlotte NesbittNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0002-2873-153X
Suhail AslamNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0003-4205-814X
Ealish SwiftNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0001-6884-4881
Harriet WilliamsNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0002-8009-9236
Gail HaywardNuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK.ORCID 0000-0003-0852-627X
University of Oxford · GBUniversity Medical Center Groningen · NL

Funding

Department of Health 16/45/01Department of Health NIHR300105
6 · The paper itself

Abstract

backgroundCurrent options for temperature measurement in children presenting to primary care include either electronic axillary or infrared tympanic thermometers. Non-contact infrared thermometers could reduce both the distress of the child and the risk of cross-infection.

objectivesThe objective of this study was to compare the use of non-contact thermometers with the use of electronic axillary and infrared tympanic thermometers in children presenting to primary care.

designMethod comparison study with a nested qualitative study.

settingPrimary care in Oxfordshire.

participantsChildren aged ≤ 5 years attending with an acute illness.

interventionsTwo types of non-contact infrared thermometers [i.e. Thermofocus (Tecnimed, Varese, Italy) and Firhealth (Firhealth, Shenzhen, China)] were compared with an electronic axillary thermometer and an infrared tympanic thermometer.

main outcome measuresThe primary outcome was agreement between the Thermofocus non-contact infrared thermometer and the axillary thermometer. Secondary outcomes included agreement between all other sets of thermometers, diagnostic accuracy for detecting fever, parental and child ratings of acceptability and discomfort, and themes arising from our qualitative interviews with parents.

resultsA total of 401 children (203 boys) were recruited, with a median age of 1.6 years (interquartile range 0.79-3.38 years). The readings of the Thermofocus non-contact infrared thermometer differed from those of the axillary thermometer by -0.14 °C (95% confidence interval -0.21 to -0.06 °C) on average with the lower limit of agreement being -1.57 °C (95% confidence interval -1.69 to -1.44 °C) and the upper limit being 1.29 °C (95% confidence interval 1.16 to 1.42 °C). The readings of the Firhealth non-contact infrared thermometer differed from those of the axillary thermometer by -0.16 °C (95% confidence interval -0.23 to -0.09 °C) on average, with the lower limit of agreement being -1.54 °C (95% confidence interval -1.66 to -1.41 °C) and the upper limit being 1.22 °C (95% confidence interval 1.10 to 1.34 °C). The difference between the first and second readings of the Thermofocus was -0.04 °C (95% confidence interval -0.07 to -0.01 °C); the lower limit was -0.56 °C (95% confidence interval -0.60 to -0.51 °C) and the upper limit was 0.47 °C (95% confidence interval 0.43 to 0.52 °C). The difference between the first and second readings of the Firhealth thermometer was 0.01 °C (95% confidence interval -0.02 to 0.04 °C); the lower limit was -0.60 °C (95% confidence interval -0.65 to -0.54 °C) and the upper limit was 0.61 °C (95% confidence interval 0.56 to 0.67 °C). Sensitivity and specificity for the Thermofocus non-contact infrared thermometer were 66.7% (95% confidence interval 38.4% to 88.2%) and 98.0% (95% confidence interval 96.0% to 99.2%), respectively. For the Firhealth non-contact infrared thermometer, sensitivity was 12.5% (95% confidence interval 1.6% to 38.3%) and specificity was 99.4% (95% confidence interval 98.0% to 99.9%). The majority of parents found all methods to be acceptable, although discomfort ratings were highest for the axillary thermometer. The non-contact thermometers required fewer readings than the comparator thermometers. LIMITATIONS: A method comparison study does not compare new methods against a reference standard, which in this case would be central thermometry requiring the placement of a central line, which is not feasible or acceptable in primary care. Electronic axillary and infrared tympanic thermometers have been found to have moderate agreement themselves with central temperature measurements.

conclusionsThe 95% limits of agreement are > 1 °C for both non-contact infrared thermometers compared with electronic axillary and infrared tympanic thermometers, which could affect clinical decision-making. Sensitivity for fever was low to moderate for both non-contact thermometers. FUTURE WORK: Better methods for peripheral temperature measurement that agree well with central thermometry are needed.

trial registrationCurrent Controlled Trials ISRCTN15413321.

fundingThis project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in

Indexed as

Body TemperatureInfrared RaysAxillaChild, PreschoolEquipment DesignFemaleHumansInfantInterviews as TopicMalePrimary Health CareSensitivity and SpecificityThermometersTympanic MembraneCHILDFEVERPRIMARY HEALTH CARESENSITIVITY AND SPECIFICITYTEMPERATURETHERMOMETERS

Identifiers

PMID33111663
PMCPMC7681337
OpenAlexW3097467577

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.