ReviewDer Orthopade2020
[Early assessment of the risk of later implantloosening using Roentgen Sterophotogrammetric Analysis (RSA)].
Review in Der Orthopade, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 5 citations in OpenAlex.
- [Implant anchorage: In vivo and in vitro analyses : Clusters for implant anchorage and safety].Orthopadie (Heidelberg, Germany) · 2024Review
- Is TKA femoral implant stability improved by pressure applied cement? a comparison of 2 cementing techniques.BMC musculoskeletal disorders · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAseptic implant loosening is the most common cause of implant revisions in total hip and total knee arthroplasty. Roentgen Stereophotogrammetric Analysis (RSA) represents the current gold standard for the in-vivo assessment of implant fixation. PRESENT SITUATION: Long-term clinical trials have shown that continuous implant migration within the first two postoperative years correlates strongly with a later aseptic loosening. Thus, the implant migration measured with RSA can be regarded as a reliable surrogate marker for later implant loosening. Over the past 40 years, RSA has been continuously further developed, and the model-based RSA approach has reduced the effort involved since markers attached to implant are no longer needed. PERSPECTIVES: The RSA method is gaining importance in the certification process of new orthopaedic implants-for example, the Dutch Orthopedic Society has recommended phased-introduction and RSA studies for new hip implants. Furthermore, in the context of the new EU Medical Device Regulation (MDR), which took effect in May 2017, RSA gained relevance for investigating clinically unproven implants. Critics who associate MDR with hindering innovation can be countered in that the RSA method provides a predictive assessment of implant fixation after only two years of follow-up, which is significantly shorter than standard long-term clinical trials.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.