ArticleHeliyon2020
The biomechanical performance of the night-time Providence brace: experimental and finite element investigations.
Article in Heliyon, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 11 citations in OpenAlex.
- A novel spinal orthosis with embedded shape memory alloy for adolescent idiopathic scoliosis.Biomedical engineering online · 2026Article
- Providence Bracing in Idiopathic Scoliosis: A Scoping Review.Journal of the Pediatric Orthopaedic Society of North America · 2026Review
- Wearable Devices in Scoliosis Treatment: A Scoping Review of Innovations and Challenges.Bioengineering (Basel, Switzerland) · 2025Review
- Enhancing Orthotic Treatment for Scoliosis: Development of Body Pressure Mapping Knitwear with Integrated FBG Sensors.Sensors (Basel, Switzerland) · 2025Article
- Optimized braces for the treatment of adolescent idiopathic scoliosis: A study protocol of a prospective randomised controlled trial.PloS one · 2024Article
- Finite element analysis in brace treatment on adolescent idiopathic scoliosis.Medical & biological engineering & computing · 2022Review
Corrections and comments
- Erratum issued
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The main goal of this study was to investigate the performance of a night-time Providence brace, which alters stress distribution in the growth plates and ultimately result in a reduced Cobb angle, from a biomechanical standpoint, using experimental and in-silico tools. A patient with a mild scoliosis (Cobb angle = 17) was chosen for this study. Applied forces from the Providence brace on the patient's rib cage and pelvis were measured using flexible force pads, and the measured forces were then imported to the generated FE model, and their effects on both curvature and stress distribution were observed. The measured mean forces applied by the brace were 29.4 N, 24.7 N, 22.4 N, and 37.6 N in the posterior pelvis, anterior pelvis, superior thorax, and inferior thorax, respectively, in the supine position. Results of the FE model showed that there is curvature overcorrection, and also Cobb angle was reduced from 17°, in the initial configuration, to 3.4° right after using the brace. The stress distribution, resulted from the FE model, in the patient's growth plate with the brace in the supine position, deviates from that of a scoliotic individual without the brace, and was in favor of reducing the Cobb angle. It was observed that by wearing the night time brace, unbalanced stress distribution on the lumbar vertebrae caused by the scoliotic spine's curvatures, can be somehow compensated. The method developed in this study can be employed to optimize existing scoliosis braces from the biomechanical standpoint.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.