ArticleThe British journal of radiology2021
Influence of a novel deep-learning based reconstruction software on the objective and subjective image quality in low-dose abdominal computed tomography.
Article in The British journal of radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Two Deep Image Reconstructions for a 320-Row CT: Review of Clinical ApplicationsCurrent medical imaging · 2026Review
- Deep learning CT reconstruction improves liver metastases detection.Insights into imaging · 2024Article
- Assessment of image quality and impact of deep learning-based software in non-contrast head CT scans.Scientific reports · 2024Article
- Impact of AI-Based Post-Processing on Image Quality of Non-Contrast Computed Tomography of the Chest and Abdomen.Diagnostics (Basel, Switzerland) · 2024Article
- Evaluation of the impact of a novel denoising algorithm on image quality in dual-energy abdominal CT of obese patients.European radiology · 2023Article
- Deep-Learning-Based Image Denoising in Imaging of Urolithiasis: Assessment of Image Quality and Comparison to State-of-the-Art Iterative Reconstructions.Diagnostics (Basel, Switzerland) · 2023Article
- A Feasibility Study to Evaluate Replacing Conventional Computed Tomography at 120 KVP with Low Radiation Dose and Low Iodine Intake Based on Body Mass Index-Adapted Abdominal Computed Tomography Angiography in 291 Patients.Medical science monitor : international medical journal of experimental and clinical research · 2023Article
- Determination of lower radiation dose limit for automatic measurement of adipose tissue.Journal of applied clinical medical physics · 2023Article
- Facilitating standardized COVID-19 suspicion prediction based on computed tomography radiomics in a multi-demographic setting.European radiology · 2022Article
- Influence of a Deep Learning Noise Reduction on the CT Values, Image Noise and Characterization of Kidney and Ureter Stones.Diagnostics (Basel, Switzerland) · 2022Article
- Evaluation of Apparent Noise on CT Images Using Moving Average Filters.Journal of digital imaging · 2022Article
- Performance evaluation of a deep learning image reconstruction (DLIR) algorithm in "double low" chest CTA in children: a feasibility study.La Radiologia medica · 2021Article
- Evaluation of Low-dose Computed Tomography Images Reconstructed Using Artificial Intelligence-based Adaptive Filtering for Denoising: A Comparison with Computed Tomography Reconstructed with Iterative Reconstruction Algorithm.Journal of medical physicsArticle
- Virtual Autopsy in Medicolegal Investigations: A Systematic Review of Accuracy and Practical Utility.International journal of applied & basic medical researchReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesModern reconstruction and post-processing software aims at reducing image noise in CT images, potentially allowing for a reduction of the employed radiation exposure. This study aimed at assessing the influence of a novel deep-learning based software on the subjective and objective image quality compared to two traditional methods [filtered back-projection (FBP), iterative reconstruction (IR)].
methodsIn this institutional review board-approved retrospective study, abdominal low-dose CT images of 27 patients (mean age 38 ± 12 years, volumetric CT dose index 2.9 ± 1.8 mGy) were reconstructed with IR, FBP and, furthermore, post-processed using a novel software. For the three reconstructions, qualitative and quantitative image quality was evaluated by means of CT numbers, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in six different ROIs. Additionally, the reconstructions were compared using SNR, peak SNR, root mean square error and mean absolute error to assess structural differences.
resultsOn average, CT numbers varied within 1 Hounsfield unit (HU) for the three assessed methods in the assessed ROIs. In soft tissue, image noise was up to 42% lower compared to FBP and up to 27% lower to IR when applying the novel software. Consequently, SNR and CNR were highest with the novel software. For both IR and the novel software, subjective image quality was equal but higher than the image quality of FBP-images.
conclusionThe assessed software reduces image noise while maintaining image information, even in comparison to IR, allowing for a potential dose reduction of approximately 20% in abdominal CT imaging. ADVANCES IN KNOWLEDGE: The assessed software reduces image noise by up to 27% compared to IR and 48% compared to FBP while maintaining the image information.The reduced image noise allows for a potential dose reduction of approximately 20% in abdominal imaging.