Evidence map›Paper›PMID 33094034›Full record

ArticleIEEE journal of translational engineering in health and medicine2020

Quantification of Resting-State Ballistocardiogram Difference Between Clinical and Non-Clinical Populations for Ambient Monitoring of Heart Failure.

Isaac Sungjae Chang, Susanna Mak, Narges Armanfard, Jennifer Boger, Sherry L Grace, Amaya Arcelus, Caroline Chessex, Alex Mihailidis

Abstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Isaac Sungjae ChangInstitute of Biomaterials and Biomedical Engineering, University of TorontoONM5S 3G9Canada.
Susanna MakDivision of CardiologyDepartment of MedicineMount Sinai HospitalTorontoONM5G 1X5Canada.
Narges ArmanfardDepartment of Electrical and Computer EngineeringMcGill UniversityMontrealQCH3A 0G4Canada.
Jennifer BogerDepartment of Systems Design EngineeringUniversity of WaterlooWaterlooONN2L 3G1Canada.
Sherry L GraceFaculty of HealthYork UniversityTorontoONM3J IP3Canada.
Amaya ArcelusToronto Rehabilitation Institute, University Health NetworkTorontoONM5T 2S8Canada.
Caroline ChessexToronto Rehabilitation Institute, University Health NetworkTorontoONM5T 2S8Canada.
Alex MihailidisToronto Rehabilitation Institute, University Health NetworkTorontoONM5T 2S8Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A ballistocardiogram (BCG) is a versatile bio-signal that enables ambient remote monitoring of heart failure (HF) patients in a home setting, achieved through embedded sensors in the surrounding environment. Numerous methods of analysis are available for extracting physiological information using the BCG; however, most have been developed based on non-clinical subjects. While the difference between clinical and non-clinical populations are expected, quantification of the difference may serve as a useful tool. In this work, the differences in resting-state BCGs of the two cohorts in a sitting posture were quantified. An instrumented chair was used to collect the BCG from 29 healthy adults and 26 NYHA HF class I and II patients while seated without any stress test for five minutes. Five 20-second epochs per subject were used to calculate the waveform fluctuation metric at rest (WFMR). The WFMR was obtained in two steps. The ensemble average of the segmented BCG heartbeats within an epoch were calculated first. Mean square errors (MSE) between different ensemble average pairs were then retrieved. The MSEs were averaged to produce the WFMR. The comparison showed that the clinical cohort had higher fluctuation than the non-clinical population and had at least 82.2% separation, suggesting that greater errors may result when existing algorithms were used. The WFMR acts as a bridge that may enable important features, including the addition of error margins in parameter estimation and ways to devise a calibration strategy when resting-state BCG is unstable.

Indexed as

ambient monitoringBallistocardiogramheart failureresting-state

Identifiers

PMID33094034
PMCPMC7571868

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.