Evidence map›Paper›PMID 33088862›Full record

ArticleThe archives of bone and joint surgery2020

Biomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: an Animal in Vitro Study.

Mohammad Javad Ein-Afshar, Mostafa Shahrezaee, Mohammad Hossein Shahrezaee, Seyed Reza Sharifzadeh

Abstract read
In one paragraph

Article in The archives of bone and joint surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mohammad Javad Ein-AfsharDepartment of Orthopedic Surgery, School of Medicine, AJA University of Medical Science, Tehran, Iran.
Mostafa ShahrezaeeDepartment of Orthopedic Surgery, School of Medicine, AJA University of Medical Science, Tehran, Iran.
Mohammad Hossein ShahrezaeeSchool of Dentistry, Tehran University of Medical Science, Tehran, Iran.
Seyed Reza SharifzadehDepartment of Orthopedic Surgery, School of Medicine, AJA University of Medical Science, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe present study was conducted to quantify the relationships between bone drilling process parameters (i.e., feed rate, resting time, exit rate, and drill bit diameter) and drilling outcome parameters (i.e., thrust force and maximum temperature).

methodsThis study utilized 10-cm cortical bovine samples to evaluate the effects of four independent parameters, including drill bit diameters, six different feed rates, three various resting times, and three different exit rates on thrust force and maximum temperature (MT). A total of 28 stainless steel orthopedic drill bits with a diameter of 2.5 and 3.2 mm, as well as an orthopedic handpiece were attached to the 500N load cell and an accurate linear variable differential transformer to obtain forces. Moreover, two k-type thermocouples were utilized to record the temperature-time curve near the drilling site. The data were analyzed using the two-way analysis of variance and post hoc Tukey-Kramer Honest test.

resultsMaximum thrust force (MTF) decreased by almost 230% as the drill bit diameter increased from 2.5 to 3.2 mm in the lowest feed rate. The MTF showed a 335% increase, whereas a decrease of 69% was observed as the feed rates rose from 0.5 to 3 mm/sec. Moreover, the MT decreased to 67% with an increasing exit rate from 1 to 3 mm/sec. Furthermore, a slight increase was observed in MT when the resting time increased from 0 to 2 seconds (

conclusionThe desired drilling is drilling with lower thrust force and lower final temperature of bone. Increasing feed rate can cause an increase and decline in thrust force and final temperature, respectively. The highest rates of MT were 0.5 and 1 mm/min, and the optimum feed rate would be 1.5 mm/min due to the averaged thrust force. Moreover, the resting time had no significant effects on the final temperature. Attentions to resting time would be useful to provide a more accurate, efficient, and uniform drill hole.

Indexed as

Controlled bone drillingDrilling thrust forceEfficiency of drillingHeat generation

Identifiers

PMID33088862
PMCPMC7547161

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.