Evidence map›Paper›PMID 33088162›Full record

Trial reportWorld journal of gastroenterology2020

Endoscopic ultrasound-fine needle biopsies of pancreatic lesions: Prospective study of histology quality using Franseen needle.

Petros Stathopoulos, Anika Pehl, Lutz Philipp Breitling, Christian Bauer, Tobias Grote, Thomas Mathias Gress, Carsten Denkert, Ulrike Walburga Denzer

Abstract readClinical Trial
In one paragraph

Trial report in World journal of gastroenterology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Petros StathopoulosDivision of Endoscopy, Department of Gastroenterology, Endocrinology, Metabolism and Clinical Infectiology, University Hospital Marburg, Marburg 35043, Hessen, Germany.
Anika PehlInstitute of pathology, University Hospital Marburg, Marburg 35043, Hessen, Germany.
Lutz Philipp BreitlingDivision of Endoscopy, Department of Gastroenterology, Endocrinology, Metabolism and Clinical Infectiology, University Hospital Marburg, Marburg 35043, Hessen, Germany.
Christian BauerDivision of Endoscopy, Department of Gastroenterology, Endocrinology, Metabolism and Clinical Infectiology, University Hospital Marburg, Marburg 35043, Hessen, Germany.
Tobias GroteDivision of Endoscopy, Department of Gastroenterology, Endocrinology, Metabolism and Clinical Infectiology, University Hospital Marburg, Marburg 35043, Hessen, Germany.
Thomas Mathias GressDivision of Endoscopy, Department of Gastroenterology, Endocrinology, Metabolism and Clinical Infectiology, University Hospital Marburg, Marburg 35043, Hessen, Germany.
Carsten DenkertInstitute of pathology, University Hospital Marburg, Marburg 35043, Hessen, Germany.
Ulrike Walburga DenzerDivision of Endoscopy, Department of Gastroenterology, Endocrinology, Metabolism and Clinical Infectiology, University Hospital Marburg, Marburg 35043, Hessen, Germany. uwdenzer@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe introduction of fine needle biopsies (FNB) to clinical practice presents a changing trend towards histology in the endoscopic ultrasound-guided tissue acquisition (EUS-TA).

aimTo evaluate the clinical performance of a new FNB needle, the 22-gauge (22G) Franseen needle, when sampling pancreatic solid lesions.

methodsConsecutive patients with an indication for EUS-TA for the assessment of pancreatic solid lesions were included in this prospective, single-center, single-arm trial. Each patient underwent a puncture of the lesion two times using the 22G Franseen needle and the obtained samples were directly placed into formalin for histological analysis. The primary study endpoint was the rate of high-quality obtained specimen. Secondary endpoints included the length and diameter of the core specimen, the diagnostic accuracy and the complication rate.

resultsFrom June 2017 to December 2018, forty patients with pancreatic solid lesions (22 females; mean age 67.2 years) were enrolled. Tissue acquisition was achieved in all cases. High-quality histology, rated with Payne score 3, was obtained in 37/40 cases (92.5%) after two needle passes. The mean size of the acquired histological core tissue was 1.54 mm × 0.39 mm. The diagnostic accuracy for the correct diagnosis was 85% (34/40). Only one adverse event was occurred, consisting of a self-limiting bleeding in the puncture site.

conclusionThe 22G Franseen needle achieved according to our standardized protocol a high rate of histological core procurement, and a high diagnostic accuracy, with one minor adverse event reported.

Indexed as

Endoscopic Ultrasound-Guided Fine Needle AspirationPancreatic NeoplasmsAgedEndosonographyFemaleHumansNeedlesPancreasProspective StudiesEndosonographyFine needle biopsyFranseen needleHistologyPancreatic lesions

Identifiers

PMID33088162
PMCPMC7545386

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.