Evidence map›Paper›PMID 33086002›Full record

ArticleJournal of the American Society for Mass Spectrometry2020

USB-Powered Coated Blade Spray Ion Source for On-Site Testing Using Transportable Mass Spectrometry.

Josha Jager, Arjen Gerssen, Janusz Pawliszyn, Saskia S Sterk, Michel W F Nielen, Marco H Blokland

Open access · hybridAbstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. ACS environmental Au · 2022
    Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
  9. Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Josha JagerWageningen Food Safety Research (WFSR), Part of Wageningen University & Research, P.O. Box 230, 6700 AE Wageningen, The Netherlands.
Arjen GerssenWageningen Food Safety Research (WFSR), Part of Wageningen University & Research, P.O. Box 230, 6700 AE Wageningen, The Netherlands.
Janusz PawliszynDepartment of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L3G1, Canada.ORCID http://orcid.org/0000-0002-9975-5811
Saskia S SterkWageningen Food Safety Research (WFSR), Part of Wageningen University & Research, P.O. Box 230, 6700 AE Wageningen, The Netherlands.
Michel W F NielenWageningen Food Safety Research (WFSR), Part of Wageningen University & Research, P.O. Box 230, 6700 AE Wageningen, The Netherlands.ORCID http://orcid.org/0000-0003-4634-0249
Marco H BloklandWageningen Food Safety Research (WFSR), Part of Wageningen University & Research, P.O. Box 230, 6700 AE Wageningen, The Netherlands.ORCID http://orcid.org/0000-0002-3751-6065
Wageningen University & Research · NLUniversity of Waterloo · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

On-site testing in food analysis using mass spectrometry (MS) requires miniaturization of vacuum systems, mass analyzers, sample cleanup, and ionization sources. In this study, a simple coated blade spray (CBS) ion source was developed that enables high voltage generation on the blade by ubiquitous certified (micro-)USB On-The-Go devices like smartphones, tablets, and power banks. CBS is capable of performing both analyte enrichment by solid-phase microextraction (SPME) material coated on the metal substrate and direct-spray ionization. The USB-CBS device was used on two different MS systems, a transportable single-quadrupole and a benchtop triple-quadrupole tandem MS. Various characteristics of the USB-CBS device, including high voltage generation and angular positioning, were studied. The potential of the newly developed device for food safety applications is demonstrated by banned and regulated veterinary drugs such as β-agonists and sulfonamide antibiotics, covering a wide range of molecular weights and polarities. The results highlight the potential of the developed, simplified, inexpensive (less than 10 USD), and universal vendor-independent USB-powered CBS ion source coupled with MS(/MS) systems for semiquantitative applications, in laboratories, and in future on-site food quality and safety testing. Apart from that, most likely on-site environmental, biomedical, and forensic testing will also benefit from this USB-CBS instrumental development that is compatible with any atmospheric inlet MS system.

Identifiers

PMID33086002
PMCPMC7659368
OpenAlexW3094146489

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.