Evidence map›Paper›PMID 33084745›Full record

ArticleArquivos brasileiros de cardiologia2020

Standardizing Radiation Exposure during Cardiac Catheterization in Children with Congenital Heart Disease: Data from a Multicenter Brazilian Registry.

João Luiz Manica, Vanessa Oliveira Duarte, Marcelo Ribeiro, Adam Hartley, Ricardo Petraco, Carlos Pedra, Raul Rossi

Open access · diamondAbstract readMulticenter Study
In one paragraph

Article in Arquivos brasileiros de cardiologia, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.3field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Radiation Exposure in Pediatric Interventional Procedures.Cardiovascular and interventional radiology · 2021
    Review
  6. The Importance of Benchmark Radiation.Arquivos brasileiros de cardiologia · 2020
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 3 countries.

João Luiz ManicaInstituto de Cardiologia / Fundação Universitária de Cardiologia (IC/FUC),Porto Alegre, RS - Brasil.ORCID 0000-0002-5714-9880
Vanessa Oliveira DuarteInstituto de Cardiologia / Fundação Universitária de Cardiologia (IC/FUC),Porto Alegre, RS - Brasil.
Marcelo RibeiroHospital do Coração, São Paulo, SP - Brasil.
Adam HartleyNational Heart and Lung Institute, Imperial College London, Hammersmith Hospital, Londres - Reino Unido.
Ricardo PetracoNational Heart and Lung Institute, Imperial College London, Hammersmith Hospital, Londres - Reino Unido.
Carlos PedraHospital do Coração, São Paulo, SP - Brasil.
Raul RossiInstituto de Cardiologia / Fundação Universitária de Cardiologia (IC/FUC),Porto Alegre, RS - Brasil.
Fundação Universitária de Cardiologia · BRHospital do Coração · BRUnited Nations Industrial Development Organization · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn recent years the increasing number of interventional procedures has resulted in growing concerns regarding radiation exposure for patients and staff. The evaluation of radiation exposure in children is difficult due to the great variability in body weight. Therefore, reference levels of radiation are not well defined for this population.

objectivesTo study and validate the ratio of dose-area product (DAP) to patient weight as a reference measurement of radiation for hemodynamic congenital heart disease procedures in children.

methodsThis observational multicenter study uses data obtained from a Brazilian registry of cardiac catheterization for congenital heart disease from March 2013 to June 2014. Inclusion criteria were all patients aged <18 years old undergoing hemodynamic procedures for congenital heart disease, with recorded DAP doses. P-value < 0.05 was considered as statistically significant.

resultsThis study evaluated 429 patients with median age and weight of 50 (10, 103) months and 15 (7, 28) kg, respectively. Median DAP was 742.2 (288.8, 1,791.5) μGy.m2. There was a good correlation between DAP and weight-fluoroscopic time product(rs=0.66). No statistically significant difference was observed in DAP/weight ratio between therapeutic and diagnostic procedures. There was a wide variation in the DAP/weight ratio among the therapeutic procedures (p<0.001).

conclusionsThe DAP/weight ratio is the simplest and most applicable measurement to evaluate radiation exposure in a pediatric population. Although there is limited literature available, the doses obtained in the present study were similar to those previously found. Ongoing research is important to evaluate the impact of strategies to reduce radiation exposure in this population (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0).

Indexed as

Heart Defects, CongenitalRadiation ExposureAdolescentAgedBrazilCardiac CatheterizationChildChild, PreschoolFluoroscopyHumansRadiation DosageRadiography, InterventionalRegistries

Identifiers

PMID33084745
PMCPMC8133734
OpenAlexW3093953832

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked