ArticleNano letters2020
Direct Three-Dimensional Imaging of an X-ray Nanofocus Using a Single 60 nm Diameter Nanowire Device.
Article in Nano letters, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 13 citations in OpenAlex.
- Deep Sub-Wavelength 3D Imaging Using a Single Nanowire Detector.Nano letters · 2025Article
- Energy-Selective X-Ray Detection Using Chemically Tunable High-Z Nanocomposites.Materials (Basel, Switzerland) · 2025Article
- Analytical and Numerical Investigation of Nanowire Transistor X-ray Detector.Materials (Basel, Switzerland) · 2023Article
- Design and performance of a dedicated coherent X-ray scanning diffraction instrument at beamline NanoMAX of MAX IV.Journal of synchrotron radiation · 2022Article
- NanoMAX: the hard X-ray nanoprobe beamline at the MAX IV Laboratory.Journal of synchrotron radiation · 2021Article
- Off-axis multilayer zone plate with 16 nm × 28 nm focus for high-resolution X-ray beam induced current imaging.Journal of synchrotron radiation · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Nanoscale X-ray detectors could allow higher resolution in imaging and diffraction experiments than established systems but are difficult to design due to the long absorption length of X-rays. Here, we demonstrate X-ray detection in a single nanowire in which the nanowire axis is parallel to the optical axis. In this geometry, X-ray absorption can occur along the nanowire length, while the spatial resolution is limited by the diameter. We use the device to make a high-resolution 3D image of the 88 nm diameter X-ray nanofocus at the Nanomax beamline, MAX IV synchrotron, by scanning the single pixel device in different planes along the optical axis. The images reveal fine details of the beam that are unattainable with established detectors and show good agreement with ptychography.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.