Evidence map›Paper›PMID 33083136›Full record

ArticlePeerJ2020

A noninvasive flexible conformal sensor for accurate real-time monitoring of local cerebral edema based on electromagnetic induction.

Jingbo Chen, Gen Li, Mingsheng Chen, Gui Jin, Shuanglin Zhao, Zelin Bai, Jun Yang, Huayou Liang, Jia Xu, Jian Sun and 1 more

Abstract read
In one paragraph

Article in PeerJ, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. [Magnetic induced phase shift detection system based on a novel sensor for cerebral hemorrhage].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024
    Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Jingbo ChenCollege of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China.
Gen LiSchool of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing, China.
Mingsheng ChenCollege of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China.
Gui JinCollege of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China.
Shuanglin ZhaoCollege of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China.
Zelin BaiCollege of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China.
Jun YangCollege of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China.
Huayou LiangChina Aerodynamics Research and Development Center Low Speed Aerodynamic Institute, Mianyang, China.
Jia XuCollege of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China.
Jian SunCollege of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China.
Mingxin QinCollege of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cerebral edema (CE) is a non-specific pathological swelling of the brain secondary to any type of neurological injury. The real-time monitoring of focal CE mostly found in early stage is of great significance to reduce mortality and disability. Magnetic Induction Phase Shift (MIPS) is expected to achieve non-invasive continuous monitoring of CE. However, most existing MIPS sensors are made of hard materials which makes it difficult to accurately retrieve CE information. In this article, we designed a conformal two-coil structure and a single-coil structure, and studied their sensitivity map using finite element method (FEM). After that, the conformal MIPS sensor that is preferable for local CE monitoring was fabricated by flexible printed circuit (FPC). Next, physical experiments were conducted to investigate its performance on different levels of simulated CE solution volume, measurement distance, and bending. Subsequently, 14 rabbits were chosen to establish CE model and another three rabbits were selected as controls. The 24-hour MIPS real-time monitoring experiments was carried out to verify that the feasibility. Results showed a gentler attenuation trend of the conformal two-coil structure, compared with the single-coil structure. In addition, the novel flexible conformal MIPS sensor has a characteristic of being robust to bending according to the physical experiments. The results of animal experiments showed that the sensor can be used for CE monitoring. It can be concluded that this flexible conformal MIPS sensor is desirable for local focusing measurement of CE and subsequent multidimensional information extraction for predicting model. Also, it enables a much more comfortable environment for long-time bedside monitoring.

Indexed as

Bedside monitoringCerebral edemaConformal two-coil structureFlexible conformal mips sensorLocal focusing measurementMagnetic Induction Phase Shift

Identifiers

PMID33083136
PMCPMC7546241

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.