ArticleBMC cardiovascular disorders2020
Lesion outline and thermal field distribution of ablative in vitro experiments in myocardia: comparison of radiofrequency and laser ablation.
Article in BMC cardiovascular disorders, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
Abstract
objectivesTo explore the lesion outline and thermal field distribution of radiofrequency ablation (RFA) and laser ablation (LA) in myocardial ablation in vitro. MATERIALS AND
methodsTwenty-four fresh porcine hearts were ablated with RFA or LA in vitro. The radiofrequency electrode or laser fiber and two parallel thermocouple probes were inserted into the myocardium under ultrasound guidance. The output power for RFA was 20 W/s and for LA was 5 W/s, and the total thermal energies were 1200 J, 2400 J, 3600 J, and 4800 J. The range of ablation lesions was measured, and temperature data were recorded simultaneously.
resultsAll coagulation zones were ellipsoidal with clear boundaries. The center of LA was carbonized more obviously than that of RFA. With the accumulation of thermal energy and the extended time, all the ablation lesions induced by both RFA and LA were enlarged. By comparing the increase in thermal energy between the two groups, both the short-axis diameter and the volume change showed significant differences between the 1200 J and 3600 J groups and between the 2400 J and 4800 J groups (all P < 0.05). Both the short-axis diameter and the volume of the coagulation necrosis zone formed by LA were always larger than those of RFA at the same accumulated thermal energy. The temperatures of the two thermocouple probes increased with each energy increment. At the same accumulated energy, the temperature of LA was much higher than that of RFA at the same point. The initial temperature increase at 0.5 cm of LA was rapid. The temperature reached 43 °C and the accumulated energy reached 1200 J after approximately 4 min. After that the temperature increased at a slower rate to 70 C. For the RFA at the point of 0.5 cm, the initial temperature increased rapidly to 30 °C with the same accumulated energy of 1200 J after only 1 min. In the range of 4800 J of accumulated thermal energy, only the temperature of LA at the point of 0.5 cm exceeded 60 °C when the energy reached approximately 3000 J.
conclusionsBoth RFA and LA were shown to be reliable methods for myocardial ablation. The lesion outline and thermal field distribution of RFA and LA should be considered when performing thermal ablation in the intramyocardial septum during hypertrophic obstructive cardiomyopathy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.