Evidence map›Paper›PMID 33081095›Full record

ArticleSensors (Basel, Switzerland)2020

A "Single-Use" Ceramic-Based Electrochemical Sensor Chip Using Molecularly Imprinted Carbon Paste Electrode.

Aaryashree No Family Name, Yuuto Takeda, Momoe Kanai, Akihiko Hatano, Yasuo Yoshimi, Masahito Kida

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 21 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Aaryashree No Family NameDepartment of Applied Chemistry, Shibaura Institute of Technology, Tokyo 135-8548, Japan.ORCID 0000-0002-5009-9489
Yuuto TakedaDepartment of Applied Chemistry, Shibaura Institute of Technology, Tokyo 135-8548, Japan.
Momoe KanaiDepartment of Applied Chemistry, Shibaura Institute of Technology, Tokyo 135-8548, Japan.
Akihiko HatanoDepartment of Chemistry, Shibaura Institute of Technology, Saitama 337-8570, Japan.
Yasuo YoshimiDepartment of Applied Chemistry, Shibaura Institute of Technology, Tokyo 135-8548, Japan.ORCID 0000-0002-5529-2720
Masahito KidaR&D Center, Technology Development Division, NGK Spark Plug, Co., Komaki 485-8510, Japan.
Shibaura Institute of Technology · JPNGK Spark Plug (Japan) · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An inexpensive disposable electrochemical drug sensor for the detection of drugs (vancomycin, meropenem, theophylline, and phenobarbital) is described. Molecularly imprinted polymer (MIP) templated with the target drugs was immobilized on the surface of graphite particles using a simple radical polymerization method and packed into the working electrode of a three-electrode ceramic-based chip sensor. Differential pulse voltammetry (DPV) was used to determine the relationship between the response current and the concentration of the targeted drug while using one sensor chip for one single operation. The time required for each DPV measurement was less than 2 min. Concentrations corresponding to the therapeutic range of these drugs in plasma were taken into account while performing DPV. In all the cases, the single-used MIP sensor showed higher sensitivity and linearity than non-imprinted polymer. The selectivity test in drugs with a structure similar to that of the target drugs was performed, and it was found that MIP-based sensors were more selective than the untreated ones. Additionally, the test in whole blood showed that the presence of interfering species had an insignificant effect on the diagnostic responses of the sensor. These results demonstrate that the disposable MIP-sensor is promising for quick and straightforward therapeutic drug monitoring to prevent the toxic side effects and the insufficient therapeutic effect due to the overdose and underdose, respectively.

Indexed as

Biosensing TechniquesElectrochemical TechniquesMolecular ImprintingCarbonCeramicsElectrodesLimit of DetectionCarbonceramic chipdisposable sensorelectrochemical sensormolecularly imprinted polymertherapeutic drug monitoring

Identifiers

PMID33081095
PMCPMC7602806
OpenAlexW3093360947

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked