Evidence map›Paper›PMID 33079238›Full record

Trial reportSurgical endoscopy2021

Evaluation of new motorized articulating laparoscopic instruments by laparoscopic novices using a standardized laparoscopic skills curriculum.

Daniel Uysal, Claudia Gasch, Rouven Behnisch, Felix Nickel, Beat Peter Müller-Stich, Markus Hohenfellner, Dogu Teber

Open access · hybridAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Surgical endoscopy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 10 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Daniel UysalMedical School, University of Frankfurt, Frankfurt, Germany.
Claudia GaschDepartment of Urology, Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany. claudia.gasch@med.uni-heidelberg.de.
Rouven BehnischInstitute of Medical Biometry and Informatics (IMBI), University of Heidelberg, Heidelberg, Germany.
Felix NickelDepartment of General, Visceral, and Transplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Beat Peter Müller-StichDepartment of General, Visceral, and Transplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany.
Markus HohenfellnerDepartment of Urology, Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany.
Dogu TeberDepartment of Urology, Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany.
Heidelberg University · DEGoethe University Frankfurt · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMotorized articulating laparoscopic instruments (ALI) offer more degrees of freedom than conventional laparoscopic instruments (CLI). However, a difficult learning curve and complex instrument handling are still a problem of ALI. We compared the performance of new prototypes of motorized ALI with CLI in a series of standardized laparoscopic tasks performed by laparoscopic novices. Further, usability of the new ALI was assessed.

methodsA randomized cross-over study with 50 laparoscopic novices who either started with CLI and then changed to ALI (CA) or vice versa (AC) was conducted. All participants performed the European training in basic laparoscopic urological skills (E-BLUS) with each instrument in given order. Time and errors were measured for each exercise. Instrument usability was assessed.

resultsOverall, using CLI was significantly faster (CLI 4:27 min vs. ALI 4:50 min; p-value 0.005) and associated with fewer exercise failures in needle guidance (CLI 0 vs. ALI 12; p-value 0.0005) than ALI. Median amount of errors was similar for both instruments. Instrument sequence did not matter, as CA and AC showed comparable completion times. Regarding the learning effect, participants were significantly faster in the second attempt of exercises than in the first. In the needle guidance task, participants using CLI last demonstrated a significant speed improvement, whereas ALI were significantly slower in the second run. Regarding usability, CLI were preferred over ALI due to lighter weight and easier handling. Nevertheless, participants valued ALI's additional degrees of freedom.

conclusionUsing new motorized ALI in the E-BLUS examination by laparoscopic novices led to a worse performance compared to CLI. An explanation could be that participants felt overwhelmed by ALI and that ALI have an own distinct learning curve. As participants valued ALI's additional degrees of freedom, however, a future application of ALI could be for training purposes, ideally in combination with CLI.

Indexed as

AdultClinical CompetenceCross-Over StudiesCurriculumFemaleHumansLaparoscopyMaleYoung AdultE-BLUSHandheld robotic deviceLaparoscopyMotorized articulating laparoscopic instrumentsTrainingUrology

Identifiers

PMID33079238
PMCPMC7819923
OpenAlexW3092943585

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.