ArticleSkeletal radiology2021
Comparison of T1-weighted turbo spin echo and out-of-phase T1-weighted gradient echo Dixon MRI for the assessment of intra-medullary length of appendicular bone tumours.
Article in Skeletal radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 4 citations in OpenAlex.
- How I Do It: MRI of the Bone with Marrow-specific Sequences.Radiology · 2025Review
- Imaging of bone marrow pitfalls with emphasis on MRI.The British journal of radiology · 2023Review
- Advances in Bone Marrow Imaging: Strengths and Limitations from a Clinical Perspective.Seminars in musculoskeletal radiology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveIntra-medullary tumour length is accurately assessed on T1-weighted turbo spin echo (T1W TSE) MRI which can be relatively time consuming, whilst the gradient echo Dixon (T1W GrE Dixon) technique is a rapid sequence (imaging time ~ 30 s). The aim of this study was to determine if the out-of-phase Dixon (OP T1W GrE Dixon) sequence can produce equivalent measurements of intra-medullary tumour length compared to the T1W TSE sequence. MATERIALS AND
methodTumour length was assessed in 90 patients undergoing MRI for staging of primary bone tumours with both T1W TSE and OP T1W GrE Dixon MRI sequences at 3 T (n = 42) and 1.5 T (n = 48). Tumour length was measured independently by different observers allowing assessment of inter-observer correlation, and the correlation between measurements on T1W TSE and OP T1W GrE Dixon sequences was also determined.
resultsThere were 53 males and 37 females (mean age 36.4 years; range 2-77 years). Inter-observer correlation for tumour length on both the T1W TSE and T1W OP GrE Dixon sequences was very good (ICC = 0.94-0.98), and measurement of tumour length comparing T1W TSE and T1W GrE Dixon was also very good (ICC = 0.91-0.99). In 4 cases, tumour length was significantly overestimated on T1W TSE images due to extensive reactive marrow oedema, but more accurately determined on the OP sequence when compared to resection specimens.
conclusionsThe OP T1W GrE Dixon sequence is comparable to T1W TSE for assessment of the intra-medullary length of appendicular bone tumours, and more accurate in the presence of extensive reactive marrow oedema.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.