Observational studyBMC pregnancy and childbirth2020
Comparison of oral glucose tolerance test and ambulatory glycaemic profiles in pregnant women in Uganda with gestational diabetes using the FreeStyle Libre flash glucose monitoring system.
Observational study in BMC pregnancy and childbirth, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 26 citations in OpenAlex.
- Glucose monitoring based on habitual dietary intake as an alternative screening test for diagnosing gestational diabetes mellitus: a systematic review.BMC pregnancy and childbirth · 2026Pooled it
- The Role of Continuous Glucose Monitoring in Managing Hyperglycaemia First Detected in Pregnancy: A Narrative Review.Diabetes, obesity & metabolism · 2026Review
- Exploring Continuous Glucose Monitoring in Gestational Diabetes: A Systematic Review.Life (Basel, Switzerland) · 2025Review
- Performance of flash continuous glucose monitoring and glycemic marker correlations in Chinese pregnant women with non-type 1 diabetes.World journal of diabetes · 2025Article
- The Efficacy and Acceptability of Flash Glucose Monitoring in Pregnant Women with Gestational Diabetes Mellitus: A Systematic Review.Journal of clinical medicine · 2024Review
- Oral glucose tolerance test and continuous glucose monitoring for gestational diabetes diagnosis: a survey study of women and health care professionals.Archives of gynecology and obstetrics · 2024Article
- A new continuous glucose monitor for the diagnosis of gestational diabetes mellitus: a pilot study.BMC pregnancy and childbirth · 2023Article
- The association between an oral glucose tolerance test performed at term pregnancy and obstetric outcomes.Obstetric medicine · 2022Article
- Development and evaluation of an online questionnaire to identify women at high and low risk of developing gestational diabetes mellitus.BMC pregnancy and childbirth · 2022Article
- Continuous Glucose Monitoring for the Diagnosis of Gestational Diabetes Mellitus: A Pilot Study.Journal of diabetes research · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 2 countries.
Funding
Abstract
backgroundThe diagnosis of hyperglycaemia in sub-Saharan Africa (SSA) is challenging. Blood glucose levels obtained during oral glucose tolerance test (OGTT) may not reflect home glycaemic profiles. We compare OGTT results with home glycaemic profiles obtained using the FreeStyle Libre continuous glucose monitoring device (FSL-CGM).
methodsTwenty-eight women (20 with gestational diabetes [GDM], 8 controls) were recruited following OGTT between 24 and 28 weeks of gestation. All women wore the FSL-CGM device for 48-96 h at home in early third trimester, and recorded a meal diary. OGTT was repeated on the final day of FSL-CGM recording. OGTT results were compared with ambulatory glycaemic variables, and repeat OGTT was undertaken whilst wearing FSL-CGM to determine accuracy of the device.
resultsFSL-CGM results were available for 27/28 women with mean data capture 92.8%. There were significant differences in the ambulatory fasting, post-prandial peaks, and mean glucose between controls in whom both primary and secondary OGTT was normal (n = 6) and those with two abnormal OGTTs or "true" GDM (n = 7). There was no difference in ambulatory mean glucose between these controls and the 13 women who had an abnormal primary OGTT and normal repeat OGTT. These participants had significantly lower body mass index (BMI) than the true GDM group (29.0 Vs 36.3 kg/m
conclusionDiagnosis of GDM on a single OGTT identifies a proportion of women who do not have a significantly higher home glucose levels than controls. This raises questions about factors which may affect the reproducibility of OGTT in this population, including food insecurity and atypical phenotypes of diabetes. More investigation is needed to understand the suitability of the OGTT as a diagnostic test in sub-Saharan Africa.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.