Evidence map›Paper›PMID 33075114›Full record

ArticlePloS one2020

Sensitivity to interaural time differences and localization accuracy in cochlear implant users with combined electric-acoustic stimulation.

Monika Körtje, Uwe Baumann, Timo Stöver, Tobias Weissgerber

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Article
  3. The Effects of Middle-ear Stiffness on the Auditory Brainstem Neural Encoding of Phase.Journal of the Association for Research in Otolaryngology : JARO · 2022
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Monika KörtjeAudiological Acoustics, ENT Department, University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt am Main, Germany.ORCID 0000-0003-2432-7609
Uwe BaumannAudiological Acoustics, ENT Department, University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt am Main, Germany.
Timo StöverENT Department, University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt am Main, Germany.
Tobias WeissgerberAudiological Acoustics, ENT Department, University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt am Main, Germany.ORCID 0000-0002-0327-1274
Goethe University Frankfurt · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesIn this study, localization accuracy and sensitivity to acoustic interaural time differences (ITDs) in subjects using cochlear implants with combined electric-acoustic stimulation (EAS) were assessed and compared with the results of a normal hearing control group.

methodsEight CI users with EAS (2 bilaterally implanted, 6 unilaterally implanted) and symmetric binaural acoustic hearing and 24 normal hearing subjects participated in the study. The first experiment determined mean localization error (MLE) for different angles of sound incidence between ± 60° (frontal and dorsal presentation). The stimuli were either low-pass, high-pass or broadband noise bursts. In a second experiment, just noticeable differences (JND) of ITDs were measured for pure tones of 125 Hz, 250 Hz and 500 Hz (headphone presentation).

resultsExperiment 1: MLE of EAS subjects was 8.5°, 14.3° and 14.7°, (low-, high-pass and broadband stimuli respectively). In the control group, MLE was 1.8° (broadband stimuli). In the differentiation between sound incidence from front and back, EAS subjects performed on chance level. Experiment 2: The JND-ITDs were 88.7 μs for 125 Hz, 48.8 μs for 250 Hz and 52.9 μs for 500 Hz (EAS subjects). Compared to the control group, JND-ITD for 125 Hz was on the same level of performance. No statistically significant correlation was found between MLE and JND-ITD in the EAS cohort.

conclusionsNear to normal ITD sensitivity in the lower frequency acoustic hearing was demonstrated in a cohort of EAS users. However, in an acoustic localization task, the majority of the subjects did not reached the level of accuracy of normal hearing. Presumably, signal processing time delay differences between devices used on both sides are deteriorating the transfer of precise binaural timing cues.

Indexed as

Cochlear ImplantsAcoustic StimulationAdultCase-Control StudiesElectric StimulationFemaleHearing LossHumansMaleMiddle AgedNoiseSound LocalizationTime

Identifiers

PMID33075114
PMCPMC7571672
OpenAlexW3093198774

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.