Evidence map›Paper›PMID 33074300›Full record

ArticleInvestigative ophthalmology & visual science2020

Effect of Body Position on Intraocular Pressure (IOP), Intracranial Pressure (ICP), and Translaminar Pressure (TLP) Via Continuous Wireless Telemetry in Nonhuman Primates (NHPs).

Jessica V Jasien, Brian C Samuels, James M Johnston, J Crawford Downs

Open access · goldAbstract read
In one paragraph

Article in Investigative ophthalmology & visual science, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Observational
  5. Article
  6. Article
  7. Article
  8. Article
  9. Effects of head-down tilt on optic nerve sheath diameter in healthy subjects.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2023
    Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Jessica V JasienVision Science Graduate Program, School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, United States.
Brian C SamuelsDepartment of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States.
James M JohnstonDepartment of Neurosurgery, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States.
J Crawford DownsDepartment of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States.
University of Alabama at Birmingham · US

Funding

Visual Phenotyping CoreP30EY003039 · NEI · UNIVERSITY OF ALABAMA AT BIRMINGHAM · PI LAWRENCE C SINCICH · 1985 to 2026
$16.9M
IOP and OPP Fluctuation as Risk Factors for GlaucomaR01EY026035 · NEI · UNIVERSITY OF ALABAMA AT BIRMINGHAM · PI J CRAWFORD DOWNS · 2016 to 2026
$5.2M
IOP and OPP Fluctuation as Risk Factors for GlaucomaR01EY024732 · NEI · UNIVERSITY OF ALABAMA AT BIRMINGHAM · PI DOWNS, J CRAWFORD · 2015 to 2017
$820k
NEI NIH HHS P30 EY003039NEI NIH HHS R01 EY024732NEI NIH HHS R01 EY026035
6 · The paper itself

Abstract

Purpose: Recent retrospective clinical studies and animal experiments have suggested that cerebrospinal fluid pressure (CSFP) is important in glaucoma, acting through the translaminar pressure (TLP = IOP - CSFP), which directly affects the optic nerve head. In this study, IOP and intracranial pressure (ICP; a surrogate of CSFP) were measured at various body positions to quantify the determinants of TLP. Methods: We have developed an implantable wireless pressure telemetry system based on a small piezoelectric sensor with low temporal drift. Telemetry transducers were placed in the anterior chamber to measure IOP and in the brain parenchyma at eye height to measure ICP. IOP was calibrated against anterior cannulation manometry, and ICP/CSFP was calibrated against an intraparenchymal Codman ICP Express microsensor. We measured IOP, ICP, and TLP = IOP - ICP continuously at 200 Hz in three male nonhuman primates (NHPs) in three trials; pressures were then averaged for 30 seconds per body position. Relative change of IOP, ICP, and TLP from the supine (baseline) position to the seated, standing, and inverted positions were quantified. Results: TLP changed significantly and instantaneously from the supine to seated (+14 mm Hg), supine to standing (+13 mm Hg) and supine to inverted (-12 mm Hg) positions (P < 0.05). There was no significant TLP change for supine to prone. ICP showed greater relative change than IOP. Conclusions: TLP change due to body position change is driven more by ICP/CSFP than IOP. IOP, ICP, and TLP variability, coupled with telemetry, should allow us to test the hypotheses that IOP, ICP, or TLP fluctuations contribute independently to glaucoma onset or progression.

Indexed as

Monitoring, AmbulatoryAnimalsBlood PressureIntracranial PressureIntraocular PressureMacaca mulattaMalePostureRetrospective StudiesTelemetryTonometry, Ocular

Identifiers

PMID33074300
PMCPMC7585393
OpenAlexW3093054986

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials